2005
DOI: 10.1016/j.jdent.2005.01.013
|View full text |Cite
|
Sign up to set email alerts
|

An in-vitro and in-vivo methodology study of alveolar bone measurement using extra-oral radiographic alignment apparatus, Image Pro-Plus® software and a subtraction programme

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 20 publications
0
11
0
Order By: Relevance
“…Once in digital format the images were analyzed with Image-Pro Plus computer software (version 7.0) using a technique described previously. 14 A single operator carried out all the measurements on the masked images, which were repeated after two weeks. The repeatability of the methods was assessed using a paired t test to detect systematic error and an intra-class correlation coefficient to determine random error.…”
Section: Alveolar Bone Levelsmentioning
confidence: 99%
“…Once in digital format the images were analyzed with Image-Pro Plus computer software (version 7.0) using a technique described previously. 14 A single operator carried out all the measurements on the masked images, which were repeated after two weeks. The repeatability of the methods was assessed using a paired t test to detect systematic error and an intra-class correlation coefficient to determine random error.…”
Section: Alveolar Bone Levelsmentioning
confidence: 99%
“…6 Threedimensional (3D) micro computed tomography (mCT) analysis has been used to overcome these limitations to obtain conclusive research outcomes. 1,[28][29][30] Although 3D Micro CT has been used by a few researchers to analyze mandibular bone, 31,32 it has not been used for analysis of maxillary bone changes due to the lack of method to extract the volume of interest (VOI) areas in maxilla. Therefore, this study was undertaken to compare maxillary and tibial bone morphometric parameter changes resulting from estrogen deficiency induced by ovariectomy.…”
mentioning
confidence: 99%
“…The accuracy of the digital measurement methods has been examined in previous studies. As expected, the intraobserver reliability (intraclass correlation coefficient: 0.98) is more accurate than interobserver examination (0.69 and 0.65) [Shinkai et al, 2004;Rawlinson et al, 2005]. In this study, the Adobe Photoshop 7 was used to analyze the digital images.…”
Section: Discussionmentioning
confidence: 74%
“…Digital CT and X-ray images or histological sections are frequently used to quantify the amount of bone formation [Mohr et al, 2003;Shinkai et al, 2004;Rawlinson et al, 2005] Image Solutions IMSOL, Standish, Wigan (UK), Image Science Software, Berlin (Germany) and Imagic Bildverarbeitung, Glattbrugg (Switzerland)]. The accuracy of the digital measurement methods has been examined in previous studies.…”
Section: Discussionmentioning
confidence: 99%