An in vitro comparison of two modern apex locators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
37
1
9

Year Published

2007
2007
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(52 citation statements)
references
References 13 publications
2
37
1
9
Order By: Relevance
“…These studies differ in establishing the reference point from which measurement accuracy is determined. Some authors measured from the minor diameter (apical constriction) (21,22,(27)(28)(29)(30)(31)(32)(33), whereas others measured from the major diameter or apical foramen (16,23,34). EALs have traditionally afforded some latitude of acceptable error in locating the apex (21,25,26,30).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…These studies differ in establishing the reference point from which measurement accuracy is determined. Some authors measured from the minor diameter (apical constriction) (21,22,(27)(28)(29)(30)(31)(32)(33), whereas others measured from the major diameter or apical foramen (16,23,34). EALs have traditionally afforded some latitude of acceptable error in locating the apex (21,25,26,30).…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, Endex must be calibrated for each canal. Many studies (16)(17)(18) have shown precision measurements AE0.5 mm from the WL in 59%, 100%, and 68% of the specimens treated. Advances in technology have led to the development of EALs such as the Root ZX (J. Morita Co, Tustin, CA) that determine the minor diameter position using the ''ratio method,'' which allows for the simultaneous measurement of impedance at two frequencies; a quotient of impedance is then calculated and expressed as a position of the file in the canal.…”
mentioning
confidence: 99%
“…The use of electronic apex locators (EALs) to determine working length has gained increasing popularity in recent years because of their high accuracy rates (1)(2)(3)(4)(5). EALs were frequently used with a small size 15 stainless-steel endodontic hand file and numerous apex locator studies have used this file for testing purposes.…”
Section: Introductionmentioning
confidence: 99%
“…15 Jenkins y colaboradores realizaron un estudio para probar la eficacia del localizador Root ZX en presencia de una gran variedad de irrigantes, comúnmente utilizados, durante el tratamiento de endodoncia; los resultados mostraron un 81% de eficacia en ausencia de hipoclorito de sodio, un 83% en presencia de un hipoclorito de sodio al 2.25% y un 85% con un hipoclorito de sodio al 5.25%. 8 Sin embargo, estas sustancias han sido probadas de manera individual dentro del conducto, y es importante tener en cuenta que durante la limpieza y la conformación, se hace necesaria la combinación de una solución irrigante con un agente quelante para eliminar la capa de barrillo dentinal, exponer los túbulos dentinales y de esta manera facilitar la remoción de detritus, bacterias y endotoxinas que se encuentran presentes dentro del sistema radicular de conductos.…”
unclassified
“…8 Weiger y colaboradores reportaron una alta eficacia del localizador apical Root ZX en presencia del hipoclorito de sodio al 1%. 15 Otros autores como Cemal utilizaron hipoclorito de sodio al 0.5%, al 1%, al 2.65%, y al 5.25% dentro del sistema de conductos radicular y demostraron que la eficacia del Root ZX no se afecta al aplicar estas sustancias en diferentes concentraciones. 31 Después de una completa revisión de literatura, se observó que ningún estudio evaluaba la eficacia del localizador apical con la combinación de una sustancia irrigadora y un agente quelante, siendo éste un procedimiento de rutina durante la preparación de los conductos radiculares.…”
unclassified