Abstract:An infrared detector based on single wall nanotube (SWNT) film suspended on double-cantilever is proposed and fabricated. The operation principle of the proposed infrared detector is a simultaneous measurement of electrical resistance change induced by thermal radiation on the SWNT film and mechanical stress induced from bimetal-type double-cantilever. Measured temperature coefficient of resistance (TCR) of an proposed bolometer was -1.82 %/K in the temperature range of 20~80 celsius temperature degree. The re… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.