An interdigitated microelectrode based aptasensor for real-time and ultratrace detection of four organophosphorus pesticides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
2
1

Relationship

4
5

Authors

Journals

citations
Cited by 35 publications
(19 citation statements)
references
References 37 publications
0
19
0
Order By: Relevance
“…The S-protein is tested with tenfold increase from 10 -5 to 10 -1 ng/mL in 0.1×PBS solution. Here the upper-limit concentration of 10 -1 ng/mL is determined by observing the saturation phenomenon [31,32] This indicates the sensor's primary performance of output monotonicity In Fig. 1a, the linearity of the transient curves become worse after 10 s when the concentration is high.…”
Section: Resultsmentioning
confidence: 99%
“…The S-protein is tested with tenfold increase from 10 -5 to 10 -1 ng/mL in 0.1×PBS solution. Here the upper-limit concentration of 10 -1 ng/mL is determined by observing the saturation phenomenon [31,32] This indicates the sensor's primary performance of output monotonicity In Fig. 1a, the linearity of the transient curves become worse after 10 s when the concentration is high.…”
Section: Resultsmentioning
confidence: 99%
“…The solution of fluorescent particles (FluoSpheres ® Carboxylate-Modified Microspheres, 1 μm, nile red fluorescent 535/575, 2% solids) was diluted 1000 times by 0.5× SSC. Even though both ACEO and ACET microflows were generated by nonuniform electric fields between electrodes, for electrodes with a thermally insulative substrate, flow patterns were fundamentally different [31,32]. While ACEO flows went from the electrode edge to its inside, ACET flows followed the direction of thermal gradients, i.e., going opposite to the ACEO directions, in this case.…”
Section: Frequency Optimizationmentioning
confidence: 89%
“…Because both were larger than the miRNA-16b tested here, the DEP effect was much more pronounced for enrichment. Thereby, it was reasonable to have a better response at 10 kHz for miRNA-16b detection due to the dominance of the ACET effect for miRNA enrichment [24,31].…”
Section: Frequency Optimizationmentioning
confidence: 99%
“…AuNPs colorimetric assay combined with aptamer SS2-55 can realize the high-throughput screening of OPs [ 71 , 72 ]. Zhang et al [ 73 ] constructed an aptamer SS2-55-modified micro-interdigitated electrode chip for quantitative detection of the four OPs. The LODs for the target OPs were 0.24–1.67 fM.…”
Section: Rapid Multi-residue Detection Methods Based On Different mentioning
confidence: 99%