1978
DOI: 10.1088/0305-4608/8/8/006
|View full text |Cite
|
Sign up to set email alerts
|

An investigation of elastic moduli of vanadium-chromium alloys

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
14
0

Year Published

1987
1987
2018
2018

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(17 citation statements)
references
References 11 publications
3
14
0
Order By: Relevance
“…In this case, the materials with relatively low values of Young's moduli close to the values of human tissue (10-60 GPa) are needed to ensure biomechanical compatibility and uniform load distribution, avoiding bone degradation. [16], green [18] and black [17] colors. The data obtained by the PAW-SQS method in this paper are denoted by red triangles.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this case, the materials with relatively low values of Young's moduli close to the values of human tissue (10-60 GPa) are needed to ensure biomechanical compatibility and uniform load distribution, avoiding bone degradation. [16], green [18] and black [17] colors. The data obtained by the PAW-SQS method in this paper are denoted by red triangles.…”
Section: Resultsmentioning
confidence: 99%
“…It is therefore important to establish how different computational methods deal with the instability in simulations of elastic properties of bcc Ti alloys. The elastic moduli of Ti-V system have been studied in several experimental [16][17][18] and theoretical works [19][20][21]. In Ref.…”
Section: Introductionmentioning
confidence: 99%
“…The elastic constants of five polycrystalline and four single crystal Cr-V alloys were measured using the resonant ultrasound spectroscopy in this study. In addition, Lenkkeri and Lahteenkorva [40] previously measured the elastic constants of six polycrystalline Cr-V alloys, single crystal Cr and V using the pulse echo method.…”
Section: Resultsmentioning
confidence: 99%
“…Due to the unavailability of moduli data for the a-Cr and r phases, the bulk modulus of 161 GPa reported for pure Cr at room temperature [41] was used for both of these phases as an approximation, due to the high amount of Cr likely to be present in these phases.…”
Section: Modelling Of the Bulk Modulus Of Phasesmentioning
confidence: 99%
“…The Poisson's ratios of a-Cr and r phase have yet to be determined, and hence, the reported value of 0.21 for pure Cr at room temperature [41] was used for both of these phases here as an approximation.…”
Section: Modelling Of Poisson's Ratios Of the Phasesmentioning
confidence: 99%