2013
DOI: 10.1109/tpwrd.2012.2231099
|View full text |Cite
|
Sign up to set email alerts
|

An Open Platform for Rapid-Prototyping Protection and Control Schemes With IEC 61850

Abstract: Communications is becoming increasingly important to the operation of protection and control schemes. Although offering many benefits, using standards-based communications, particularly IEC 61850, in the course of the research and development of novel schemes can be complex. This paper describes an open source platform which enables the rapidprototyping of communications-enhanced schemes. The platform automatically generates the data model and communications code required for an Intelligent Electronic Device (… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 58 publications
(17 citation statements)
references
References 13 publications
0
17
0
Order By: Relevance
“…These could include IEEE 1588 frames and data from other measurement locations; assuming a maximum of four simultaneous competing frames and a transmission delay of 0.58 µs per frame [23], the maximum queuing delay is 4 × 0.58 µs. t M U and t CC can be estimated as 12 µs and 9.5 µs, respectively, based on the measurements in [24] for approximately double the frame size, but this depends on the performance of the platform. Combining all of these factors, the worst case delay can be estimated as: Further delays are introduced by the protection system and they arise from the window-based processing required by the fault detection signal calculation and DWT.…”
Section: Measurement and Communications Delays Within DC Substationmentioning
confidence: 99%
“…These could include IEEE 1588 frames and data from other measurement locations; assuming a maximum of four simultaneous competing frames and a transmission delay of 0.58 µs per frame [23], the maximum queuing delay is 4 × 0.58 µs. t M U and t CC can be estimated as 12 µs and 9.5 µs, respectively, based on the measurements in [24] for approximately double the frame size, but this depends on the performance of the platform. Combining all of these factors, the worst case delay can be estimated as: Further delays are introduced by the protection system and they arise from the window-based processing required by the fault detection signal calculation and DWT.…”
Section: Measurement and Communications Delays Within DC Substationmentioning
confidence: 99%
“…Therefore, protection settings data can be stored alongside other system data presented in a SCL file, which facilitates data integration. 6) The SCL format is formally defined by an XML schema [26], which allows the validation of SCL files to be conducted automatically [27]. The generation and manipulation of an SCL file can be automatically performed by model-centric software such as the Eclipse Modelling Framework (more details are provided in Section III-B).…”
Section: B Key Advantages Of Using Scl As the Common Format For Protmentioning
confidence: 99%
“…A similar application of this tool is described in [27]. The exporting step is performed by the SCL Creator, as shown in Fig.…”
Section: Settings In Original Iedmentioning
confidence: 99%
“…An example where specific low-level communication code is generated is presented by Blair et al [33]. In their approach C code is automatically generated based on IEC 61850 SCL files.…”
Section: Model-driven Engineering For Smart Grid Application Developmentmentioning
confidence: 99%