2020
DOI: 10.12688/wellcomeopenres.16063.1
|View full text |Cite
|
Sign up to set email alerts
|

An optimisation of four SARS-CoV-2 qRT-PCR assays in a Kenyan laboratory to support the national COVID-19 rapid response teams

Abstract: Background: The global COVID-19 outbreak relies on a quantitative real-time polymerase chain reaction (qRT-PCR) for the detection of severe acute respiratory syndrome coronavirus (SARS-CoV-2), to facilitate the roll-out of patient care and infection control measures. There are several qRT-PCR assays with little evidence on their comparability. We report alterations to the developers’ recommendations to sustain the testing capability in our setting, where the supply of testing reagen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2

Relationship

6
0

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…Nasopharyngeal (NP) and oropharyngeal (OP) swabs were collected into a single tube and transported to KEMRI-Wellcome Trust Research Programme (KWTRP) for SARS-CoV-2 diagnosis. Briefly, the positive infections were RNA purified using a QIAGEN extraction kit followed by real-time reverse-transcription PCR (RT-PCR) (Agoti et al, 2020; Said et al, 2020).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Nasopharyngeal (NP) and oropharyngeal (OP) swabs were collected into a single tube and transported to KEMRI-Wellcome Trust Research Programme (KWTRP) for SARS-CoV-2 diagnosis. Briefly, the positive infections were RNA purified using a QIAGEN extraction kit followed by real-time reverse-transcription PCR (RT-PCR) (Agoti et al, 2020; Said et al, 2020).…”
Section: Methodsmentioning
confidence: 99%
“…The RRTs collected nasopharyngeal (NP) and oropharyngeal (OP) swabs into a single tube and transported them to the KEMRI-Wellcome Trust Research Programme (KWTRP) for SARS-CoV-2 diagnosis. The laboratory diagnostic protocol for SARS-CoV-2 at KWTRP has been described elsewhere 8,10 Briefly, the positive infections were identified using a two stage procedure, first, viral RNA purification using a QIAGEN extraction kit followed by real-time reverse-transcription PCR (RT-PCR) using one or two of four SARS-CoV-2 detection assays that we deployed at the centre since the beginning of the pandemic namely the Berlin Charite protocol, Europe Virus Archive Global (EVA-g) protocol, Beijing Genomics Institute (BGI) protocol and Da An Commercial Kit protocol (Said et al, 2020).…”
Section: Methods Detailsmentioning
confidence: 99%
“…For the qRT-PCR assay, the European Virus Archive-GLOBAL (EVAg) primer/probe set containing 1.75μl primer probe mix, 3.75μl Nuclease free water, 2.5μl TaqMan™ Fast Virus master mix and 2.5μl of template RNA was used [12]. Cycling conditions were 50˚C for 5min, 95˚C for 20sec then 40 cycles of 95˚C for 3sec and 58˚C for 45sec on the QuantStudio 5 and 7 qRT-PCR systems (Applied Biosystems, CA).…”
Section: Quantitative Reverse Transcription Pcr Assaysmentioning
confidence: 99%
“…Furthermore, data obtained from the PCR analyser were in Ct values. These were reviewed and interpreted using a Ct cut-off of 36, as determined by Mohammed et al (2020), interpreting those values of less than and greater than the cut-off as positive and negative test results, respectively [12]. The qRT-PCR machine also gave an 'undetermined' result among the Ct values, and these were interpreted as negative test results.…”
Section: Quantitative Reverse Transcription Pcr Assaysmentioning
confidence: 99%
“…For the qRT-PCR assay, the European Virus Archive -GLOBAL (EVAg) primer/probe set containing 1.75μl primer probe mix, 3.75μl Nuclease free water, 2.5μl TaqMan™ Fast Virus master mix and 2.5μl of template RNA were used (12). Cycling conditions were 50°C for 5min, 95°C for 20sec then 40 cycles of 95°C for 3sec and 58°C for 45sec on the QuantStudio 5 and 7 qRT-PCR systems (Applied Biosystems, CA).…”
Section: Quantitative Reverse Transcription Pcr Assaysmentioning
confidence: 99%