2018
DOI: 10.1016/j.sab.2018.05.004
|View full text |Cite
|
Sign up to set email alerts
|

An Rf-only ion funnel interface for ion cooling in laser ablation time of flight mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
16
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 18 publications
(18 citation statements)
references
References 40 publications
2
16
0
Order By: Relevance
“…Here, the extraction of ions into high vacuum is performed with the use of an RF-only ion funnel placed on the axis downstream the nozzle exit. This approach to the ion beam extraction has been proposed in [12] and later it was further developed [13][14][15] and experimentally proven at ETH Zürich [16,17] and Stanford [18,19].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Here, the extraction of ions into high vacuum is performed with the use of an RF-only ion funnel placed on the axis downstream the nozzle exit. This approach to the ion beam extraction has been proposed in [12] and later it was further developed [13][14][15] and experimentally proven at ETH Zürich [16,17] and Stanford [18,19].…”
Section: Introductionmentioning
confidence: 99%
“…The gas flow rate through the relatively large cross section of the annular nozzle throat demanded higher pumping speed in the RF-funnel chamber. In the second design [16,17] the laser had to be focused and aligned through the whole apparatus and through the nozzle reducing the freedom in the target design and limiting the reduction of the nozzle diameter. In the third design presented in this work the laser ablation is realized orthogonal to the nozzle and funnel axis allowing the laser ablation and ion extraction to be designed independently.…”
Section: Introductionmentioning
confidence: 99%
“…An electrodynamic ion funnel has been suggested for the efficient ion collection and transportation into a mass analyzer under the ambient conditions of rarified (0.5-1 kPa) Martian atmosphere (Johnson et al, 2011). Another recent example is an RF-ion funnel for improved ion extraction in LIMS-TOF instrument with an orthogonal setup (Querci et al, 2018). In this setup, the sample is located in the chamber filled with a buffer gas (He).…”
Section: Li-tof-mss With Orthogonal Geometrymentioning
confidence: 99%
“…An ion passes through this hole into a converging-diverging nozzle that takes in high pressure, subsonic flow and outputs low pressure supersonic flow. This flow is passed through an RF-funnel which focuses Ba ++ and separates it from GXe and background impurities, and then passes it to an ion guide for further filtration [85] [86]. Next is a collision cell in which Ba ++ is converted into Ba+ by the following reaction,…”
Section: The Barium-tagging Line With the Capillary Methodsmentioning
confidence: 99%
“…Plots of the Reynolds number for GXe (left) and for LXe (right) when the capillary is designed to displace the maximum mass of fluid that can be pumped at the McGill University RF-Funnel[86].…”
mentioning
confidence: 99%