2022
DOI: 10.1007/s12161-022-02336-w
|View full text |Cite
|
Sign up to set email alerts
|

An Ultrasensitive Upconversion Fluorescence Aptasensor Based on Graphene Oxide Release and Magnetic Separation for Staphylococcus aureus Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 32 publications
1
6
0
Order By: Relevance
“…The limit of detection (LOD) of the fabricated upconversion fluorescence probe was determined to be 30 CFU/mL, based on the formula of LOD = 3 Sa/S b (3 is the factor at the 99% confidence level, Sa is the standard deviation of 10 blank upconversion fluorescence measurements, and S b is the slope of the Shigella detection calibration plot). Furthermore, in comparison with the linear range, LOD and detection time of the developed upconversion fluorescence probe with other reported methods [ 33 , 34 , 35 , 36 , 37 , 38 ] confirmed that the probe can achieve Shigella detection with high sensitivity and meets the requirements for contaminated sample detection ( Table 1 ).…”
Section: Resultssupporting
confidence: 60%
See 1 more Smart Citation
“…The limit of detection (LOD) of the fabricated upconversion fluorescence probe was determined to be 30 CFU/mL, based on the formula of LOD = 3 Sa/S b (3 is the factor at the 99% confidence level, Sa is the standard deviation of 10 blank upconversion fluorescence measurements, and S b is the slope of the Shigella detection calibration plot). Furthermore, in comparison with the linear range, LOD and detection time of the developed upconversion fluorescence probe with other reported methods [ 33 , 34 , 35 , 36 , 37 , 38 ] confirmed that the probe can achieve Shigella detection with high sensitivity and meets the requirements for contaminated sample detection ( Table 1 ).…”
Section: Resultssupporting
confidence: 60%
“…As shown in Figure 2 A, five stretching vibration bands at 1469 cm −1 , 1572 cm −1 , 2849 cm −1 , 2934 cm −1 , and 3401 cm −1 were found, and these bands belonged to the =C-H, COO- and -CH-stretching vibration, respectively (curve a) [ 32 ]. After surface modification with ADA, the four bands at around 1469 cm −1 , 1572 cm −1 , 2849cm −1 , and 2934 cm −1 disappeared, and a new stretching vibration band at 1093 cm −1 appeared, which was associated with the NH 2 -stretching vibration, validating successful modification of ADA (curve b) [ 33 ]. After surface modification with carboxyl, the band at around 3467 cm −1 disappeared, and two new stretching vibration bands at 1502 cm −1 and 1701cm −1 appeared.…”
Section: Resultsmentioning
confidence: 94%
“…Recently, Chen et al (2022b) developed a fluorescence biosensor based on magnetic Fe 3 O 4 -modified graphene oxide (MNPs@GO) for rapid and direct diagnosis of S. aureus . The biosensor employed aptamer-functionalized upconversion nanoparticles (UCNPs) in combination with MNPs@GO.…”
Section: Application Of Mnps-based Biosensor For Poctmentioning
confidence: 99%
“…The MNPs@GO-UCNP biosensor is able to detect quantitatively 13 CFU/mL. This biosensor was tested on real chicken meat samples, proving a valid system to monitor bacteria in food samples [ 82 ].…”
Section: Fluorescence-based Go Sensors For Diagnosticsmentioning
confidence: 99%