2020
DOI: 10.1007/s00202-020-00970-3
|View full text |Cite
|
Sign up to set email alerts
|

An update on the performance of reactive energy meters under non-sinusoidal conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
0
0
4

Year Published

2020
2020
2025
2025

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 16 publications
0
0
0
4
Order By: Relevance
“…The study published by Hollister [1] in 1915 was one of the first studies to conduct research on the performance of active energy meters under non-ideal conditions in which an analytical approach reflected the essence of the physical meaning of active power under nonsinusoidal conditions and emphasized the impact of the presence of harmonic components on electric energy measurement systems. Since then, several other studies [2], [3], [4], [5], [6], [7], [8] have been published contemplating analytical, computational, or practical studies that cover the performance of active or reactive energy meters under nonsinusoidal conditions.…”
Section: B Literature Reviewmentioning
confidence: 99%
“…The study published by Hollister [1] in 1915 was one of the first studies to conduct research on the performance of active energy meters under non-ideal conditions in which an analytical approach reflected the essence of the physical meaning of active power under nonsinusoidal conditions and emphasized the impact of the presence of harmonic components on electric energy measurement systems. Since then, several other studies [2], [3], [4], [5], [6], [7], [8] have been published contemplating analytical, computational, or practical studies that cover the performance of active or reactive energy meters under nonsinusoidal conditions.…”
Section: B Literature Reviewmentioning
confidence: 99%
“…Entre as metodologias comumente utilizadas em medidores de faturamento, encontra-se o método do triângulo de potências [2]. Assim, os equacionamentos propostos por esse método são apresentados no decorrer dessa seção.…”
Section: Método Do Triângulo De Potênciasunclassified
“…Dentre os efeitos que a conexão das cargas não lineares proporciona, pode-se mencionar ainda sua influência na medição e no faturamento da energia elétrica. De fato, o custo da energia elétrica para consumidores de média tensão é baseado não somente na energia/potência ativa, mas também na reativa [2] e no fator de potência. Todavia, para condições de sinais distorcidos de tensão e/ou corrente elétrica, não existe um consenso na literatura sobre a metodologia adequada para o cálculo da energia/potência reativa [3].…”
Section: Introductionunclassified
See 2 more Smart Citations