Proceedings of the XXXVIII Iberian Latin American Congress on Computational Methods in Engineering 2017
DOI: 10.20906/cps/cilamce2017-0561
|View full text |Cite
|
Sign up to set email alerts
|

Análise Térmica De Alvenaria Estrutural Em Situação De Incêndio: Um Estudo Do Gradiente Térmico

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 0 publications
0
3
0
1
Order By: Relevance
“…For the mortar joints, the values of specific heat, thermal conductivity and specific mass (Figure 7b) were those tabulated in previous papers [21,43]. For the BC1 and PC1 models, data reported by Incropera and DeWitt [44] was used to define the specific heat, thermal conductivity, and specific mass of the air (Figure 7c) inside the hollows of concrete blocks and prisms.…”
Section: Numerical Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…For the mortar joints, the values of specific heat, thermal conductivity and specific mass (Figure 7b) were those tabulated in previous papers [21,43]. For the BC1 and PC1 models, data reported by Incropera and DeWitt [44] was used to define the specific heat, thermal conductivity, and specific mass of the air (Figure 7c) inside the hollows of concrete blocks and prisms.…”
Section: Numerical Analysismentioning
confidence: 99%
“…Values of specific heat, thermal conductivity and specific mass of the concrete units (Figure 7a) were those tabulated in EN 1992-1-2 [42] for dry normal-weight concrete with siliceous aggregates. For the mortar joints, the values of specific heat, thermal conductivity and specific mass (Figure 7b) were those tabulated in previous papers [21,43]. For the BC1 and PC1 models, data reported by Incropera and DeWitt [44] was used to define the specific heat, thermal conductivity, and specific mass of the air (Figure 7c) inside the hollows of concrete blocks and prisms.…”
Section: Numerical Analysismentioning
confidence: 99%
“…The specific mass of the mortar was calculated from the mass proportion available in Oliveira [12], obtaining a value of 2180 kg/m³. The thermal properties of the mortar required for the modelling, such as specific heat and thermal conductivity, were adopted as available in Rodovalho, Simões and Corrêa [18]. In the air mass, internal to the cavities, an initial temperature of 17 °C was also applied and a total of 9360 solid elements of the FC3D8 "fluid" family, with dimensions of approximately 1 cm were used.…”
Section: Thermal Simulation Characteristicsmentioning
confidence: 99%
“…Por outro lado, a alvenaria estrutural, apesar de largamente utilizada por projetistas como sistema construtivo, ainda é deficitária de dados sobre seu comportamento a temperaturas elevadas. Entretanto, observa-se nos últimos anos um maior número de trabalhos nacionais neste tema focados em alvenaria estrutural (ROSEMANN, 2011;RIGÃO, 2015;LEITE et al, 2016;DÉSIR e ZANIN, 2017;RODOVALHO et al, 2017;RODOVALHO e CORRÊA, 2019, LIMA et al, 2018 A maioria dos ensaios de paredes em escala real ou mesmo pequenas paredes requerem equipamentos de grande porte, para simular o carregamento do qual o elemento estará submetido em obra, possuem relativa complexidade de construção dos corpos de prova e têm custo elevado para sua execução. Desta forma, ensaios de prismas cerâmicos tornaram-se a principal forma para avaliação de alvenarias.…”
Section: Introductionunclassified