2004
DOI: 10.1143/jjap.43.3999
|View full text |Cite
|
Sign up to set email alerts
|

Analyses of Alignment Measurement Error

Abstract: Friedrich Paschen war von 190 1 bis I924 Abstract.full professor of physics d t the University of Tubingen There he worked on the three subject areas radiation law [determination of u and thus h by Walther Gerlach), w i e s formulae of line spectrd (Paschen series) and the Zseman effect (Passhen-Back-Effekt) A Rowland grating provided the necessary high resolution In particular the theoretical interpretation of the measured atomic spectrd in mdgnetic fields finally led, i n collaboration with Sommerfeld and hi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2004
2004
2021
2021

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 3 publications
0
10
0
Order By: Relevance
“…We have shown the reason that asymmetrical pupil transmittance distribution causes TIS. 4) The distribution creates a distorted image and a measurement shift, TIS. This TIS is the amplitude-error-induced shift.…”
Section: Tis and Pupil Transmittance Distributionmentioning
confidence: 99%
See 3 more Smart Citations
“…We have shown the reason that asymmetrical pupil transmittance distribution causes TIS. 4) The distribution creates a distorted image and a measurement shift, TIS. This TIS is the amplitude-error-induced shift.…”
Section: Tis and Pupil Transmittance Distributionmentioning
confidence: 99%
“…If the symmetrical phase difference between the 0th ray and the other diffraction rays (W ns ) is =2 [rad], we can remove the distortion of the image caused by the amplitude error caused by asymmetrical pupil transmittance distribution. 4) Namely, W ns ¼ =2 leads ÁI ¼ 0 in eqs. (10), ( 13) and ( 14).…”
Section: Fia Focus Optimizationmentioning
confidence: 99%
See 2 more Smart Citations
“…Good wafer alignment is invaluable in lithography, dicing, or bonding, as it permits the consistent application of process parameters. Endeavors in wafer alignment can be broadly classified as efforts to ͑a͒ improve wafer placement and holding, 1-3 ͑b͒ study alignment error sources, [4][5][6] and ͑c͒ monitor the wafer position. [7][8][9][10] Techniques reported thus far for wafer position monitoring include the use of ͑i͒ imaging of marks with a CCD camera, 7 ͑ii͒ imaging of marks with a series of photosensors, 8 ͑iii͒ sensing of diffracted light from marks, 5,9 and ͑iv͒ observation of moiré patterns.…”
Section: Introductionmentioning
confidence: 99%