1996
DOI: 10.1002/elps.1150171020
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and general classification of serum cryoglobulins by capillary zone electrophoresis

Abstract: The analysis and general classification of serum cryoglobulins (CG) by capillary zone electrophoresis (CZE) are described. This technique allowed the introduction of several new aspects to the analysis of CG: (i) direct detection of monoclonality of the gamma-globulins and general classification of the different CG types, (ii) a tenfold decrease in sample size, (iii) direct quantification of the cryoprecipitate without the need for further chemical analysis, and (iv) mathematical correction for the coprecipita… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0
1

Year Published

1997
1997
2017
2017

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 27 publications
(11 citation statements)
references
References 16 publications
0
10
0
1
Order By: Relevance
“…66,67 The prevalence of circulating cryoglobulins in the HCV-infected population is close to 50%, 68 but only 15% of people in that group show clinical signs of cryoglobulinemia. 69 The prevalence of circulating cryoglobulins in hematologic and rheumatologic diseases is likely underreported.…”
Section: Questionsmentioning
confidence: 99%
“…66,67 The prevalence of circulating cryoglobulins in the HCV-infected population is close to 50%, 68 but only 15% of people in that group show clinical signs of cryoglobulinemia. 69 The prevalence of circulating cryoglobulins in hematologic and rheumatologic diseases is likely underreported.…”
Section: Questionsmentioning
confidence: 99%
“…The acetonitrile performs the function of a terminating ion in eliciting the needed high field strength without being one [12]. The borate buffer was chosen because it is a general buffer used for separating proteins as well as other compounds in our lab [14]. Fenofibric acid compound migrates in the borate-carbonate buffer at about 6.5 min while the internal standard migrates ahead at about 5.5 min (Fig.…”
Section: Fenofibric Acidmentioning
confidence: 99%
“…CZE for fenofibric acid: 7 g boric acid, 7 g sodium carbon-ate (Mallinckrodt, St. Louis, MO, USA) and 5 g/L polyethylene glycol 6000 (Fisher Scientific, Fair Lawn, NJ, USA) were used for the CZE analysis [14].…”
Section: Buffersmentioning
confidence: 99%
“…For the electrophoretic separation, a buffer similar to that used previously for separating serum proteins was chosen [17]. This buffer gives good and rapid separation for immunoglobulins separating them from other serum proteins in less than 6 min and reveals the presence of monoclonal bands.…”
Section: Resultsmentioning
confidence: 99%
“…The electrophoresis buffer was composed of 5 g boric aid, 5 g sodium carbonate and 0.3 g PEG dissolved in 100 mL water, pH 8.9 [17]. The PEG buffer consisted of PEG (2.2%) in phosphate buffer, 10 mmol/L, pH 7.1 containing 0.5% sodium chloride, stored at 0-47C.…”
Section: Chemicals and Buffersmentioning
confidence: 99%