2006
DOI: 10.2116/analsci.22.545
|View full text |Cite
|
Sign up to set email alerts
|

Analysis and Isolation of Cationic Rhenium(I) and Ruthenium(II) Multinuclear Complexes Using Size-Exclusion Chromatography

Abstract: Various cationic rhenium(I) and ruthenium(II) mono-and multinuclear complexes were successfully separated by sizeexclusion chromatography (SEC), using a 50:50 (v/v) mixture of methanol and acetonitrile with CH3CO2NH4 as an eluent. The logarithms of the molecular weights were accurately linear in the distribution coefficients: for linear-shaped rhenium(I) multinuclear complexes, log MW = -2.86KSEC + 5.24 (r = -0.990 and n = 15); for ring-shaped rhenium(I) multinuclear complexes, log MW = -2.94KSEC + 5.40 (r = -… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
26
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
6
3

Relationship

4
5

Authors

Journals

citations
Cited by 23 publications
(26 citation statements)
references
References 13 publications
0
26
0
Order By: Relevance
“…The eluent was MeOH–CH 3 CN (1 : 1 v/v) containing CH 3 COONH 4 (0.15 M) and the flow rate was 6.0 mL min –1 . 56 For analytical SEC, we used two sequentially connected Shodex KW-402.5-4F columns (300 mm × 4.6 mm i.d. ), a KW400G-4A guard-column (10 mm × 4.6 mm i.d.…”
Section: Methodsmentioning
confidence: 99%
“…The eluent was MeOH–CH 3 CN (1 : 1 v/v) containing CH 3 COONH 4 (0.15 M) and the flow rate was 6.0 mL min –1 . 56 For analytical SEC, we used two sequentially connected Shodex KW-402.5-4F columns (300 mm × 4.6 mm i.d. ), a KW400G-4A guard-column (10 mm × 4.6 mm i.d.…”
Section: Methodsmentioning
confidence: 99%
“…One equivalent of dppph was added to the reaction solution, which was subsequently refluxed for 24 h, giving the target molecule [Ring-Ru1] 5+ as the major product (process C), as indicated by size-exclusion chromatography (SEC) analysis of the reaction solution ( Figure S1c ). 31 Through recycling size-exclusion chromatography (RSEC) and recrystallization, [Ring-Ru1] (PF 6 ) 5 was isolated in 44% isolated yield. Its 1 H NMR spectrum is shown in Figure 2 .…”
Section: Results and Discussionmentioning
confidence: 99%
“…and a JAI LC-9201 recycling preparative HPLC apparatus (Japan Analytical Industry Co.) with a JASCO 870-UV detector (the detection wavelength was chosen as 360 nm); the eluent was MeOH–MeCN (1:1 v/v) containing CH 3 COONH 4 (0.15 M), and the flow rate was 6.0 mL min –1 . 31 For analytical SEC, two sequentially connected Shodex KW-402.5-4F columns (300 mm × 4.6 mm i.d.) were used, with a KW400G-4A guard-column (10 mm × 4.6 mm i.d.…”
Section: Methodsmentioning
confidence: 99%
“…The scan rate was 200 mV s –1 . Analytical SEC 12 was conducted using an HPLC system consisting of a JASCO 880-PU pump, a pair of Shodex PROTEIN KW402.5 columns, a KW-LG guard column, a Rheodyne 7125 injector, and a JASCO MD-2010 plus UV-Vis photodiode-array detector. The column temperature was maintained at 40 °C using a JASCO 860-CO column oven.…”
Section: Methodsmentioning
confidence: 99%