Analysis and Simulation of the AVR System and Parameters Variation Effects

Abstract: The primary role of an automatic voltage regulator (AVR) is to regulate the reactive power and voltage magnitude. The system modeled consists of the amplifier, exciter, sensor and stabilizer or proportional-integral-derivative (PID) controller. The state-space technique is used to model the system. Their characteristics and behavior are also briefly discussed. Results of the simulation studies on the AVR system using Matlab are presented. By examining the parameters of the stabilizer and controller, the genera… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
2

Year Published

2007
2007
2021
2021

Publication Types

Select...
5
3
2

Relationship

1
9

Authors

Journals

citations
Cited by 29 publications
(9 citation statements)
references
References 6 publications
0
7
0
2
Order By: Relevance
“…In general, the mechanical and electrical measured parameters used to identify the model of steam power plant are translated into suitable transfer functions for various components in the power plant [1]. The model selected in this investigation is the turbine speed control system presented in a two-area system i.e.…”
Section: A Overviewmentioning
confidence: 99%
“…In general, the mechanical and electrical measured parameters used to identify the model of steam power plant are translated into suitable transfer functions for various components in the power plant [1]. The model selected in this investigation is the turbine speed control system presented in a two-area system i.e.…”
Section: A Overviewmentioning
confidence: 99%
“…For mathematical modeling and transfer function of the four components, these components must be linearized, which takes into account the major time constant and ignores the saturation or other nonlinearities. The reasonable transfer function of these components may be represented, respectively, as follows [14][15][16][17][18][19]].…”
Section: B) Model Of An Avr Systemmentioning
confidence: 99%
“…In this presented work, three area hydro-thermal reheat interconnected power system have been developed by using PI and FUZZY LOGIC controllers to illustrate the performance of load frequency control using MATLAB/SIMULINK software [10]. Several types of simulink models for different cases are developed with those controllers to obtain better dynamic behavior [2]. Frequency deviation plots for different cases are obtained as shown in figures.…”
Section: B) Fuzzy Logic Controllersmentioning
confidence: 99%