1954
DOI: 10.1021/ac60089a011
|View full text |Cite
|
Sign up to set email alerts
|

Analysis Data for Ternary System Isopropyl Alcohol-Isopropyl Ether-Water

Abstract: To permit analysis of the products of isopropyl alcohol dehydration, values of the refractive index, density, and viscosity have been measured at 25°C. for isopropyl

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
3
0

Year Published

1970
1970
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 23 publications
1
3
0
Order By: Relevance
“…Neither of these inks demonstrated a significant increase or decrease in viscosity over the measured interval, with both yielding an average viscosity of 1.9 mPa s, suggesting a potential Newtonian fluid behavior, however imprecise taking into account the instrument’s resolution limitation. Nonetheless, the measured value fits very well to previously reported values for the viscosity of IPA at 20 °C . The low viscosity combined with high wettability on cured MK surfaces was advantageous for the AM process, enabling both inks to spread over the previously printed MK absorber layer and to create a PhG template with micrometer-sized thickness.…”
Section: Resultssupporting
confidence: 88%
See 1 more Smart Citation
“…Neither of these inks demonstrated a significant increase or decrease in viscosity over the measured interval, with both yielding an average viscosity of 1.9 mPa s, suggesting a potential Newtonian fluid behavior, however imprecise taking into account the instrument’s resolution limitation. Nonetheless, the measured value fits very well to previously reported values for the viscosity of IPA at 20 °C . The low viscosity combined with high wettability on cured MK surfaces was advantageous for the AM process, enabling both inks to spread over the previously printed MK absorber layer and to create a PhG template with micrometer-sized thickness.…”
Section: Resultssupporting
confidence: 88%
“…Nonetheless, the measured value fits very well to previously reported values for the viscosity of IPA at 20 °C. 56 The low viscosity combined with high wettability on cured MK surfaces was advantageous for the AM process, enabling both inks to spread over the previously printed MK absorber layer and to create a PhG template with micrometer-sized thickness.…”
Section: Resultsmentioning
confidence: 99%
“…There is little agreement between the published data for the listed physical properties of the pure 2-isopropoxypropane. The data listed by Weissberger and coworkers (13), which are the data determined by Dreisbach and Martin (3), seem rather unreliable (2).…”
Section: Methodsmentioning
confidence: 91%
“…The analysis was carried out by measurement of specific gravity and refractive index or by the Karl Fischer method of water titration (12). The data published by Brey (2) were checked and found sufficiently accurate. A diagram containing lines of constant value of refractive index and specific gravity derived from these data was used for the analysis of the present samples.…”
Section: Methodsmentioning
confidence: 99%