2021
DOI: 10.1049/hve2.12166
|View full text |Cite
|
Sign up to set email alerts
|

Analysis for magnetic field disturbance of hybrid DC circuit breaker during breaking

Abstract: The high current of hybrid DC circuit breaker (HCB) in the process of breaking generates strong transient magnetic field (MF), which may interfere with the normal operation of driver control units (DCUs). Therefore, the analysis for transient MF disturbance is of great significance. Due to the large space scale of HCB, with the large number of power electronic devices, the numerical calculation method has the disadvantages of large consumption of resources and slow calculation speed in solving the transient MF… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…However, the waveforms in the tests show some uneven and jitter shapes, resulting in no overlap between the two kinds of waveforms. The reason for the error may be (1) The greater the pre-inflated pressure, the stronger the stress on the switch during the opening, bringing about a certain influence on the gas flow field during the opening process.…”
Section: Influence Of Gas Pressures In the Arc Extinguishing Chamber ...mentioning
confidence: 99%
“…However, the waveforms in the tests show some uneven and jitter shapes, resulting in no overlap between the two kinds of waveforms. The reason for the error may be (1) The greater the pre-inflated pressure, the stronger the stress on the switch during the opening, bringing about a certain influence on the gas flow field during the opening process.…”
Section: Influence Of Gas Pressures In the Arc Extinguishing Chamber ...mentioning
confidence: 99%
“…It is found that by integrating the SFCL with the solid-state DC circuit breaker, a high voltage is induced across the high inductance SFCL during current interruption tests. The commutation switches of main breaker utilizing IGBTs to commute and break fault current will increase the cost of power electronic components and HDCCBs 24 , 25 . Integrated-gate-commutated-thyristors (IGCTs) have the advantages of high rated current, fast commutation speed, high interference immunity, low cost, and high reliability, and thus have been widely used in DC power grids 26 .…”
Section: Introductionmentioning
confidence: 99%
“…However, in the topology, both the line commutation switch and the main circuit breaker use the mirrored pair configuration of insulated gate bipolar transistors (IGBTs) to commutate and interrupt the fault current. This significantly increases the cost of power electronic components and hybrid circuit breakers [17,18]. The integrated gate commutated thyristor (IGCT) has a high inrush current and low cost.…”
Section: Introductionmentioning
confidence: 99%