2016
DOI: 10.1063/1.4963161
|View full text |Cite
|
Sign up to set email alerts
|

Analysis method for Thomson scattering diagnostics in GAMMA 10/PDX

Abstract: We have developed an analysis method to improve the accuracies of electron temperature measurement by employing a fitting technique for the raw Thomson scattering (TS) signals. Least square fitting of the raw TS signals enabled reduction of the error in the electron temperature measurement. We applied the analysis method to a multi-pass (MP) TS system. Because the interval between the MPTS signals is very short, it is difficult to separately analyze each Thomson scattering signal intensity by using the raw sig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5

Relationship

4
1

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 17 publications
0
11
0
Order By: Relevance
“…Figure 3 shows the clear multi-pass TS signals of summed with all TS signals from all output channels of the polychromator after subtracting the noises and polychromator pre-amplifier characteristic decay signals using the newly constructed analyzing method which is shown in Ref. 21, with the pass numbers. The 8 and 10 passing TS signal intensities are larger than those of 7 and 9, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Figure 3 shows the clear multi-pass TS signals of summed with all TS signals from all output channels of the polychromator after subtracting the noises and polychromator pre-amplifier characteristic decay signals using the newly constructed analyzing method which is shown in Ref. 21, with the pass numbers. The 8 and 10 passing TS signal intensities are larger than those of 7 and 9, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…16 By adding a polarization control device, a polarizer, and a high-reflection mirror to the double-pass TS system, we previously successfully constructed over three passing MPTS systems. [17][18][19] We achieved approximately 3.6 times increased TS signals by the first to the sixth passing probing lasers through the plasma in a single laser shot. 17 Moreover, the time-dependent electron temperature measurement every 65 ns was successfully obtained.…”
Section: Introductionmentioning
confidence: 87%
“…The electron temperatures are calculated by the chi-squared method. 8,19 To increase the degraded MP laser beam power, we newly added the laser amplification system onto the normal MP configuration. We switched on the second Pockels cell to change the laser beam trajectory to the laser amplification system after passing through the polarizer, half-wave plate, Faraday rotator, and mirrors.…”
Section: Mpts System With Amplification Systemmentioning
confidence: 99%