2016
DOI: 10.1109/tie.2016.2555278
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of 37-kW Converter-Fed Induction Motor Losses

Abstract: Abstract-This paper presents an energy efficiency analysis of a 37 kW standard squirrel-cage induction motor under sinusoidal and non-sinusoidal supply. The motor losses are analyzed using the conventional IEC loss segregation method and also numerically modeled using finite element simulations. The measured and simulated loss components are compared with three different modulation methods. The overall simulated losses are in good agreement with the measured ones, but there exist differences in the loss compon… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 32 publications
(10 citation statements)
references
References 33 publications
0
10
0
Order By: Relevance
“…Induction motor losses are usually divided into five categories: stator winding losses, rotor winding losses, iron losses, mechanical losses, and additional losses [1,2]. In this paper, iron losses were of interest.…”
Section: Induction Machine Loss Segregationmentioning
confidence: 99%
See 3 more Smart Citations
“…Induction motor losses are usually divided into five categories: stator winding losses, rotor winding losses, iron losses, mechanical losses, and additional losses [1,2]. In this paper, iron losses were of interest.…”
Section: Induction Machine Loss Segregationmentioning
confidence: 99%
“…Mechanical losses are usually calculated from four or more constant loss points between 30% and 60% of the rated motor voltage by developing a curve against no-load voltage squared and then performing linear extrapolation to zero voltage [1,2]. The intersection of the extrapolation curve with the vertical axis then corresponds to the mechanical losses.…”
Section: Friction and Windage Lossesmentioning
confidence: 99%
See 2 more Smart Citations
“…The effect of lowered voltage quality on induction machines is the subject of numerous research works. For the most part, these works are focused on power losses, efficiency issues [15][16][17][18][19][20][21][22][23][24][25], torque and vibration [19,22,26,27], load-carrying capacity [4,12,14,16,20,21,23,28,29], and thermal loads [4, 5, 12-15, 17, 18, 21, 24, 27, 28, 30-35]. It should be stressed that the vast majority of the works are focused on thermal steady states.…”
Section: Introductionmentioning