2004
DOI: 10.17221/4297-cjas
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of amino acid composition of sheep colostrum by near-infrared spectroscopy

Abstract: This paper deals with changes in the basic composition of sheep colostrum within the first 72 hours a�er parturition on the one hand and with the possibility of determining the major components of sheep colostrum by near-infrared spectroscopy on the other. Levels of essential, nonessential and total amino acids in sheep colostrum were determined by near-infrared reflectance spectroscopy (NIRS). Calibration was tested using the same set of samples. NIRS results were compared with reference data and no significa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
3
0
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 7 publications
0
3
0
1
Order By: Relevance
“…Stanovení těchto minoritních složek je důležité nejen v kontrole kvality mléka, ale zejména v kontrole zdravotního a výživového stavu dojnic (Famigli-Bergamini, 1987;Illek a Pechová, 1997). Pro určení mléčného složení (majoritní i minoritní složky) je v poslední době místy popisována a používána i metoda NIR-FT (Tsenkova et al, 2000;Kukačková, et al, 2000;Jankovská a Šustová, 2003;Kráčmar et al, 2004;Šustová et al, 2006.…”
unclassified
“…Stanovení těchto minoritních složek je důležité nejen v kontrole kvality mléka, ale zejména v kontrole zdravotního a výživového stavu dojnic (Famigli-Bergamini, 1987;Illek a Pechová, 1997). Pro určení mléčného složení (majoritní i minoritní složky) je v poslední době místy popisována a používána i metoda NIR-FT (Tsenkova et al, 2000;Kukačková, et al, 2000;Jankovská a Šustová, 2003;Kráčmar et al, 2004;Šustová et al, 2006.…”
unclassified
“…This procedure is usual ly performed in mid IR or as near IR variant. Over the years a number of authors (Sjaunja, 1984 a, b, c;Sjaunja et al, 1984;Sjaunja and Andersson, 1985;Hanuš et al, 1992Hanuš et al, a, 2002Tsenkova et al, 2000;Kukačková et al, 2000;Jankovská and Šustová, 2003;Kráčmar et al, 2004;Bijgaart, 2006;Broutin, 2006;Šustová et al, 2006, 2007 have investigated calibra-tion procedures for various IR methods. This was done to measure various milk components using various indirect IR methods for result reliability and stability.…”
mentioning
confidence: 99%
“…Also the checking of time measurement stability of the instruments during inter-calibration interval is very important activity. In the last time the row of authors was interested in calibration procedures of various methods of infraanalyse on various milk component measurements, fl uoro-opto-electronic method on comatic cell count determination in milk and stability of results and samples in time at indirect methods of milk analyses (Sjaunja, 1984 a, b, c;Sjaunja et al, 1984;Sjaunja and Andersson, 1985;Hanuš et al, c, 1993Hanuš et al, a, b, c, 1995Hanuš et al, , 1997Hanuš et al, , 2001Hanuš et al, , 2002Hanuš et al, , 2003Hanuš et al, , 2008Tsenkova et al, 2000;Kukačková et al, 2000;Jankovská and Šustová, 2003;Kráčmar et al, 2004;Šustová et al, 2006, 2007Hering et al, 2008). According to ČSN 590536 the instruments have to be calibrated quarterly.…”
mentioning
confidence: 99%