Analysis of Anterior Segment Dynamics Using Anterior Segment Optical Coherence Tomography Before and After Laser Peripheral Iridotomy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 36 publications
0
16
0
Order By: Relevance
“…[7][8][9][10][11][12][13]33,52,54,55 We have demonstrated that eAS-OCT is capable of evaluating the angle configuration and providing quantitative assessments of all these parameters using one device. Recent studies indicate that several important factors may be associated with the angle closure, such as ACD, LVa, LT, iris thickness, iris curvature, and iris dynamics.…”
Section: Discussionmentioning
confidence: 96%
See 1 more Smart Citation
“…[7][8][9][10][11][12][13]33,52,54,55 We have demonstrated that eAS-OCT is capable of evaluating the angle configuration and providing quantitative assessments of all these parameters using one device. Recent studies indicate that several important factors may be associated with the angle closure, such as ACD, LVa, LT, iris thickness, iris curvature, and iris dynamics.…”
Section: Discussionmentioning
confidence: 96%
“…The most successful application of OCT has been in ophthalmology, where the technology has become an indispensable tool to image both the anterior segment (e.g., cornea and anterior chamber angle) and the posterior segment (e.g., retina) of the human eye. Clinical uses include evaluating iridocorneal angle and identifying risk factors in primary angle closure glaucoma (PACG), [3][4][5][6][7][8][9][10][11][12][13] visualizing cornea, anterior chamber, and crystalline lens in refractive surgery, such as in laser in situ keratomileusis (LASIK) and phakic or pseudophakic intraocular lens (IOL) implantation, [14][15][16][17][18][19][20] assessing the dynamic response of AS during physiological accommodation and assessing ametropia, particularly for eyes undergoing IOL surgery. Izatt et al were the first to report the use of OCT to noninvasively visualize the cornea and anterior chamber in 1994.…”
Section: Introductionmentioning
confidence: 99%
“…Anterior chamber width (ACW) was defined as the length between the scleral spurs on the two opposite sides (Zheng et al. ). Pupil diameter (PD) was measured as the distance from one side to the opposite side of the pupillary tip of the iris on the images by ASOCT.…”
Section: Methodsmentioning
confidence: 99%
“…Anterior chamber depth (ACD) was defined as the length of the central perpendicular line between the anterior surface of the lens and the posterior surface of the cornea. Anterior chamber width (ACW) was defined as the length between the scleral spurs on the two opposite sides (Zheng et al 2013). Pupil diameter (PD) was measured as the distance from one side to the opposite side of the pupillary tip of the iris on the images by ASOCT.…”
Section: Image Processingmentioning
confidence: 99%
“…The accuracy of this device is based on camera resolution and measurement distance, which avoid accommodation (Silbert et al 2013). The advantage of using an infrared automated pupillometer is that the pupil size does not change while measurements are taken, minimizing the effect of hippus (Zheng et al 2013).…”
Section: Referencesmentioning
confidence: 99%