2015
DOI: 10.1016/j.applthermaleng.2014.11.064
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of application of two-phase injector in ejector refrigeration systems for isobutane

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(9 citation statements)
references
References 13 publications
0
9
0
Order By: Relevance
“…The detailed modeling of such a hydrodynamic process is also very difficult; one possible way is to apply an Eulerian two-fluid approach [95]. When using an Eulerian two-fluid approach, a proper solution for the two-phase flow depends on the correct modeling of interphase forces and turbulence models.…”
Section: Number Of Phasesmentioning
confidence: 99%
See 1 more Smart Citation
“…The detailed modeling of such a hydrodynamic process is also very difficult; one possible way is to apply an Eulerian two-fluid approach [95]. When using an Eulerian two-fluid approach, a proper solution for the two-phase flow depends on the correct modeling of interphase forces and turbulence models.…”
Section: Number Of Phasesmentioning
confidence: 99%
“…When the fluid exiting the ejector is two-phase, both a liquid state and a vapor state exists in which either [95] (i) the primary fluid is a liquid that entrains a gas or (ii) the primary fluid is high pressure steam that entrains a liquid secondary flow. The detailed modeling of such a hydrodynamic process is also very difficult; one possible way is to apply an Eulerian two-fluid approach [95].…”
Section: Number Of Phasesmentioning
confidence: 99%
“…The utility of integral characteristic is based on their experimental designation [93,94]. At present, however, certain principles design the geometry of the ejector to provide sufficient performance [95][96][97]. In the current state of the development of numerical modelling, the calibration of models is becoming crucial with regard to experimental characteristics [97][98][99][100][101][102][103].…”
Section: Integral Parametersmentioning
confidence: 99%
“…Condensing ejectors can serve as heat transfer agents, and liquid pumps in many applications where an electric pump may be less suitable, as for example, solar activated absorption and ejection cycles. Smierciew et al [200,206] performed experimentation on such a device represented in Figure 23, in terms of operation characteristics and internal heat transfer. Further tests and analysis with isobutane were reported in [207].…”
Section: Experimental Studiesmentioning
confidence: 99%