Analysis of chemical warfare agents by portable Raman spectrometer with both 785 nm and 1064 nm excitation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
23
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 28 publications
(25 citation statements)
references
References 24 publications
1
23
1
Order By: Relevance
“…The spectral range is 200-2500 cm −1 with transmission-type volume phase grating. The spectral resolution is 15-18 cm −1 , and the detector is a thermoelectrically cooled indium gallium arsenide (InGaAs) [34]. The samples were analyzed with 60 cumulative scans with optimized laser power, aperture size, and duration (7 s) per exposure in order to achieve the best signal-to-noise ratio.…”
Section: Spectroscopic Characterizations Of 3d Printed Lattice Structuresmentioning
confidence: 99%
“…The spectral range is 200-2500 cm −1 with transmission-type volume phase grating. The spectral resolution is 15-18 cm −1 , and the detector is a thermoelectrically cooled indium gallium arsenide (InGaAs) [34]. The samples were analyzed with 60 cumulative scans with optimized laser power, aperture size, and duration (7 s) per exposure in order to achieve the best signal-to-noise ratio.…”
Section: Spectroscopic Characterizations Of 3d Printed Lattice Structuresmentioning
confidence: 99%
“…Moreover, we used Raman spectroscopy to verify the formation of C-N-C bonds because it provides strong intensity for the structure with symmetric stretches of bonds [41]. After the reaction, we found a distinct peak at 757 cm −1 , which could be attributed to the vibration of C-N-C stretching (Figure 2b) [42]. These results confirm the formation of C-N-C bonds between the unreacted double bonds of the hydrogel microparticles and the primary amine groups of streptavidin.…”
Section: Spectroscopic Analysis Of Streptavidin-conjugated Encoded Hymentioning
confidence: 99%
“…Optical techniques including infrared (IR) and Raman spectroscopies are valuable as bulk identifiers, but these methods are challenged by mixtures, especially when the component of interest is at low concentration. [30][31][32] Other methods such as ion mobility spectrometry (IMS) can detect and presumptively identify trace residues of chemicals (in some instances down to a few nanograms or less), 33 but not when these trace residues are in complex sample matrices. 34,35 Portable GC-MS systems, on the other hand, can reliably and rapidly detect and identify these substances at low concentrations, even when the substance is masked in a complex matrix.…”
Section: Portable Gas Chromatography-mass Spectrometry Backgroundmentioning
confidence: 99%