Abstract:The control rod worths of the AVR power plant for the cold and hot conditions were analyzed to verify an analysis method of reflector control rod worths. In the analysis method, the neutron-flux-weighting method was used to obtain the effective group constants of the control rod inserted in the graphite nose. The control rod worths were calculated with the core analysis code system for the High Temperature engineering Test Reactor (HTTR). The experimental values of the control rod worths were 6.47 and 6.81Xdp … Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.