2011
DOI: 10.5392/jkca.2011.11.6.252
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of CT, MRI, DITI for the Diagnosis of Abdominal Obesity and Clinical Usefulness

Abstract: This study was to find out the correlation between abdominal surface temperature and abdominal fat areas. CT and MRI methods have been used to assess abdominal fat area. Abdominal surface temperature according to abdominal fat area was also measured by DITI. 20 college students were selected as the subjects for the study. The results, showed that there were statistically different significance in abdominal fats measured by CT and MRI according to weight groups. Abdominal surface temperature gap were measured b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2013
2013
2017
2017

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…As a direct and quantitatively method of measuring abdominal fat, medical imaging using a CT or MRI is available [17,44]. The fat measuring method using CT distinguishes abdominal visceral fat and subcutaneous fat by digitizing the Hounsfield unit (HU) of the adipose tissue, through which visceral adipose tissue is measured directly and quantification is possible, thus making it the most accurate method for measuring fat content [15,16].…”
Section: Discussionmentioning
confidence: 99%
“…As a direct and quantitatively method of measuring abdominal fat, medical imaging using a CT or MRI is available [17,44]. The fat measuring method using CT distinguishes abdominal visceral fat and subcutaneous fat by digitizing the Hounsfield unit (HU) of the adipose tissue, through which visceral adipose tissue is measured directly and quantification is possible, thus making it the most accurate method for measuring fat content [15,16].…”
Section: Discussionmentioning
confidence: 99%
“…In order to clarify the mechanism of the butterfly pump system, a study on the internal structure and dynamic behavior of the butterfly pump and visualization of the 3D pump system of the female mosquito have been carried out to measure the volume capacity of the mosquito pump (Lee, Kim, & Lee, ; Kim, Seo, Lim, & Lee, ). Such studies include an evaluation of radiation exposure among workers, incidence of pneumothorax analysis of computed tomography (CT)‐guided biopsy, evaluation of exposure dose and image quality in abdominal CT scan, clinical usefulness analysis of CT for abdominal obesity diagnosis, and the objective analysis of hepatocellular carcinoma and hepatic hemangioma in Liver CT scan (Geraghty et al, ; Hwang, Ko, & Choi, ; Siegel, Schmidt, Bradley, Suess, & Hildebolt, ; Tucker et al, ; Yeo & Jeon, ). Unlike conventional X‐rays utilized in various fields of research, synchrotron radiation uses a high brightness monochromatic X‐ray beam with an intensity of several billion times (wavelength range of 107 to 1010 m).…”
Section: Introductionmentioning
confidence: 99%