Analysis of Current Ripples in Electromagnetic Actuators with Application to Inductance Estimation Techniques for Sensorless Monitoring

Abstract: Techniques for estimating the plunger position have successfully proven to support operation and monitoring of electromagnetic actuators without the necessity of additional sensors. Sophisticated techniques in this field make use of an oversampled measurement of the rippled driving current in order to reconstruct the position. However, oversampling algorithms place high demands on AD converters and require significant computational effort which are not desirable in low-cost actuation systems. Moreover, such lo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
18
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(18 citation statements)
references
References 23 publications
0
18
0
Order By: Relevance
“…Figure 6 illustrates the response of the current to a PWM voltage for two cases: an actuator without eddy currents (black) and an actuator with eddy currents (blue). In case no eddy currents are present, the response is the classical ripple which has been previously described in the work [26]. Under consideration of eddy currents, cusps in the current response appear.…”
Section: Current Ripples Induced By a Pwm Voltagementioning
confidence: 82%
See 4 more Smart Citations
“…Figure 6 illustrates the response of the current to a PWM voltage for two cases: an actuator without eddy currents (black) and an actuator with eddy currents (blue). In case no eddy currents are present, the response is the classical ripple which has been previously described in the work [26]. Under consideration of eddy currents, cusps in the current response appear.…”
Section: Current Ripples Induced By a Pwm Voltagementioning
confidence: 82%
“…Equation (26) resembles the differential equation of the electrical equivalent circuit that is shown in Figure 5. Such a circuit including a parallel resistance which accounts for losses is common in many works such as [23,26,29].…”
Section: Electrical Circuit Modelmentioning
confidence: 99%