2021
DOI: 10.1007/s11356-021-15604-9
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of equivalent thickness of geological media for lab-scale study of radon exhalation

Abstract: Geological media are widely distributed in nature. Lab-scale tests are frequently employed in radon studies for these media. Thus, it is critical to find the thickness of the medium at an experimental scale that is equivalent to the medium thickness in a real geological system. Based on the diffusion-advection transport of radon, theoretical models of the surface radon exhalation rate for homogeneous semi-infinite and finite-thickness systems were derived (denoted as Jse and Jfi, respectively). Analysis of the… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 13 publications
(1 citation statement)
references
References 26 publications
(18 reference statements)
0
1
0
Order By: Relevance
“…The closed-loop radon measurement method is the most used one to measure the radon exhalation rate. The mathematical model for the increase of radon concentration in a concentrated radon cover is as follows 21 , 22 : where C is the concentration of radon accumulated during time, Bq·m −3 ; J is the radon exhalation rate, Bq·m −2 ·s −1 ; S is the measured area, m 2 ; V is the volume of the radon collector, m 3 ; t is the unit time, s; λ is the radioactive decay constant of radon (2.1 × 10 −6 s −1 ); and are the coefficients associated with radon leakage and anti-diffusion, s −1 . Anti-diffusion refers to the diffusion of the radon in the radon collector back into the medium.…”
Section: Materials and Test Methodsmentioning
confidence: 99%
“…The closed-loop radon measurement method is the most used one to measure the radon exhalation rate. The mathematical model for the increase of radon concentration in a concentrated radon cover is as follows 21 , 22 : where C is the concentration of radon accumulated during time, Bq·m −3 ; J is the radon exhalation rate, Bq·m −2 ·s −1 ; S is the measured area, m 2 ; V is the volume of the radon collector, m 3 ; t is the unit time, s; λ is the radioactive decay constant of radon (2.1 × 10 −6 s −1 ); and are the coefficients associated with radon leakage and anti-diffusion, s −1 . Anti-diffusion refers to the diffusion of the radon in the radon collector back into the medium.…”
Section: Materials and Test Methodsmentioning
confidence: 99%