Background
Ultraviolet (UV) light-mediated photofunctionalization improves the osseointegration of pure titanium and titanium alloy (Ti6Al4V). However, little is known about the effect of UV irradiation on Ti6Al4V, used frequently in orthopedic surgery, in diabetic patients. We examined the effect of UV irradiation on Ti6Al4V in rats with type 2 diabetes.
Methods
Cylinder Ti6Al4V implants were used. Half the animals were Sprague Dawley rats (the control group), and the other half were Spontaneously Diabetic Torii fatty rats (the diabetes mellitus model). For radiological analysis, bone density was observed and calculated using 3D microcomputed tomography. Histological analysis was performed to calculate the bone–implant contact (BIC) ratio. We used Pearson correlation to analyze the correlation between average blood glucose level and BIC ratio, and between average blood glucose level and bone volume (BV) ratio.
Results
In the UV light-treated group, the BIC ratios of the normal and diabetic rats increased significantly compared with those in the untreated group at 2 weeks; at 4 weeks, the BIC ratio of the diabetic rats increased significantly, but there was no significant increase in the control animals. In both the control and diabetic groups, there was no significant difference in the BV ratios between the UV-treated and untreated implants at 2 or 4 weeks. The average blood glucose level in the 4-week group negatively correlated with the BIC and BV ratios. The average blood glucose level in the UV-treated group negatively correlated with the BIC ratio.
Conclusion
Photofunctionalization of Ti6Al4V implants may promote osseointegration in the early stages in rats with type 2 diabetes.