Analysis of half-cell potential measurement for corrosion of reinforced concrete

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
35
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 78 publications
(35 citation statements)
references
References 2 publications
0
35
0
Order By: Relevance
“…It is worth to highlight that data of corrosion potential for Stage 3 (age between 425 and 450 days) were not used in this evaluation, because the ages of the samples are very different between themselves and could compromise the comparison of data. It is possible to observe that the corrosion potential is more negative for greater moisture contents, as also evidenced by Elsener et al [7] and Leelalerkiet et al [33]; in other words, corrosion potentials at 70 days measured in the test specimens that were in humid environment (saturated) are more negative than corrosion potentials at 98 days (drying in laboratory environment between 71 and 98 days), when the test specimens had a smaller moisture content. The interaction between moisture content and corrosion potential is significant and this fact was evidenced by means of variance analysis ANOVA (Table 4), where the value of F calculated is higher than the F critical tabulated for 95% of significance.…”
Section: Influence Of Moisture Contentmentioning
confidence: 63%
“…It is worth to highlight that data of corrosion potential for Stage 3 (age between 425 and 450 days) were not used in this evaluation, because the ages of the samples are very different between themselves and could compromise the comparison of data. It is possible to observe that the corrosion potential is more negative for greater moisture contents, as also evidenced by Elsener et al [7] and Leelalerkiet et al [33]; in other words, corrosion potentials at 70 days measured in the test specimens that were in humid environment (saturated) are more negative than corrosion potentials at 98 days (drying in laboratory environment between 71 and 98 days), when the test specimens had a smaller moisture content. The interaction between moisture content and corrosion potential is significant and this fact was evidenced by means of variance analysis ANOVA (Table 4), where the value of F calculated is higher than the F critical tabulated for 95% of significance.…”
Section: Influence Of Moisture Contentmentioning
confidence: 63%
“…The factors affecting these techniques and measures to develop effective methodology in improving strength parameters using synthetic simulation approach has been proposed. Veerachai Leelalerkiet et al [13] has used Half-Cell Potential apparatus to determine the probability of rusting of steel in reinforced concrete slabs subjected to cyclic wet and dry conditions. 3D Boundary Element Method is used to study the parameters like, the rate of flow of current and the potential distributions.…”
Section: Literature Reviewmentioning
confidence: 99%
“…For example, the half-cell potential meter can be used to infer the probability of corrosion of the steel rebar from the surface of the concrete [11,12] by measuring the electrochemical potential between the rebars and a reference 'half-cell' electrode at the surface. Areas of high potential gradient are more likely to be undergoing corrosion.…”
Section: Introductionmentioning
confidence: 99%