2020
DOI: 10.1016/j.ijepes.2019.105604
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of high-voltage DC fuse’s ageing characteristics under the overload pulse current carrying mode and the caused short-circuit failure in series-resonant converter power source

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…While calculating the thermal phenomena of electrical apparatus for the rated load, the share of heat transfer by radiation and natural convection is similar (for a temperature difference of several dozen Kelvins). The conditions of heat transfer to the environment in thermal calculations are often determined using the so-called heat transfer coefficient k, which defines the total amount of heat transferred to the environment from a given surface per unit time from the cooled body to the environment [13]. The total coefficient for the fuse link placed in the air is, therefore, the sum of the coefficients of heat transfer to the environment by convection and radiation, which is shown in the following relation [14]:…”
Section: Heat Transfer During Fuse Link Operationmentioning
confidence: 99%
“…While calculating the thermal phenomena of electrical apparatus for the rated load, the share of heat transfer by radiation and natural convection is similar (for a temperature difference of several dozen Kelvins). The conditions of heat transfer to the environment in thermal calculations are often determined using the so-called heat transfer coefficient k, which defines the total amount of heat transferred to the environment from a given surface per unit time from the cooled body to the environment [13]. The total coefficient for the fuse link placed in the air is, therefore, the sum of the coefficients of heat transfer to the environment by convection and radiation, which is shown in the following relation [14]:…”
Section: Heat Transfer During Fuse Link Operationmentioning
confidence: 99%
“…Less frequently, the tests concern single and two-point contact systems, reducing the transition resistance [25][26][27][28]. In order to be able to fully prepare modular electrical devices for digitization understood as linking functions with intelligence in action, it is necessary to build, among others, FEM models and appropriate described electronics [28][29][30].…”
Section: Introductionmentioning
confidence: 99%
“…The need for more coordinated work between PV cell and fuse manufacturers is needed, reflecting the areas where this work is necessary [7]. In [8], the authors analyse fast DC fuses used in a series-resonant converter power source. Four stages of the fuse conductor are considered: the linear ageing stage, the nonlinear ageing stage, the fusing and arcing stage, and the arc-extinguishing stage.…”
Section: Introductionmentioning
confidence: 99%