2010
DOI: 10.1016/j.ajodo.2009.09.019
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of intra-arch and interarch measurements from digital models with 2 impression materials and a modeling process based on cone-beam computed tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
30
0
9

Year Published

2011
2011
2018
2018

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(39 citation statements)
references
References 24 publications
0
30
0
9
Order By: Relevance
“…20 CBCT scans of alginate and vinylpolysiloxane impressions of a typodont are both accurate for measuring intra-arch parameters (arch perimeter, arch width), but not interarch occlusal relationships. 21 Overbite, overjet, intercanine width, intermolar width and arch length discrepancy measurements from CBCT images of dried skulls are slightly smaller than the same measurements made directly on the skulls with calipers. 22 However, Little's irregularity index, overbite and overjet measurements from CBCT scans were as accurate as digitized dental impressions of patients.…”
Section: Cbct Accuracy and Reliability -Dental Arch Analysismentioning
confidence: 99%
“…20 CBCT scans of alginate and vinylpolysiloxane impressions of a typodont are both accurate for measuring intra-arch parameters (arch perimeter, arch width), but not interarch occlusal relationships. 21 Overbite, overjet, intercanine width, intermolar width and arch length discrepancy measurements from CBCT images of dried skulls are slightly smaller than the same measurements made directly on the skulls with calipers. 22 However, Little's irregularity index, overbite and overjet measurements from CBCT scans were as accurate as digitized dental impressions of patients.…”
Section: Cbct Accuracy and Reliability -Dental Arch Analysismentioning
confidence: 99%
“…operator differences: for instance, both White et al [19] and El-Zanaty et al [20] assessed only intra-examiner bias. Indeed, two or three different operators were involved in other studies, but only intra-operator variability was reported [6].…”
Section: Are Dental Measurements Taken On Plaster Casts Comparable Tomentioning
confidence: 99%
“…The authors concluded that the current scientific evidence supports the validity of digital measurements. White et al [19] tested the accuracy of the digital reproductions of dental models made by using CBCT scans, and found satisfactory values for intra-arch measurements but inaccurate inter-arch relationships. El-Zanaty et al [20] compared linear distances obtained on plaster casts and from CT head scans; the two techniques had excellent agreement.…”
Section: Are Dental Measurements Taken On Plaster Casts Comparable Tomentioning
confidence: 99%
“…Aimed at dental model scrutiny, plaster cast has been the standard for years. However, plaster models has the disadvantage of loss, breakage, ruin and necessitate corporeal packing space 4,5) .…”
Section: Introductionmentioning
confidence: 99%