2014
DOI: 10.1016/j.foodchem.2013.09.147
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of minor and trace elements in milk and yogurts by inductively coupled plasma-mass spectrometry (ICP-MS)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
100
7
1

Year Published

2014
2014
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 178 publications
(113 citation statements)
references
References 22 publications
5
100
7
1
Order By: Relevance
“…The capability of the method as a routine analysis method was estimated through the determination of the detection limits of each element studied. The limits of detection (LOD) and limits of quantifi cation (LOQ), were calculated with three and ten timed the standard deviation of the blank divided by the slope of the analytical curve, respectively [Thompson et al, 2002;Khan et al, 2014]. The values of LOD were in the range of 0.251-18.321 μg/kg as it is presented in Table 1.…”
Section: Methods Of Validationmentioning
confidence: 99%
“…The capability of the method as a routine analysis method was estimated through the determination of the detection limits of each element studied. The limits of detection (LOD) and limits of quantifi cation (LOQ), were calculated with three and ten timed the standard deviation of the blank divided by the slope of the analytical curve, respectively [Thompson et al, 2002;Khan et al, 2014]. The values of LOD were in the range of 0.251-18.321 μg/kg as it is presented in Table 1.…”
Section: Methods Of Validationmentioning
confidence: 99%
“…Although milk is a complex matrix composed of proteins, carbohydrates and lipids accuracy indicated good recovery from two different microelement spiked concentrations (10 and 50 μg L -1 ) in human milk pools (Table 4). 28 Specifically, average recovery ranged from 90% to 94% for Zn, 90% to 102% for Cu by ICP-OES and 97% to 103% for Fe by FAAS (Table 4). Blank samples and the 0.25 mg L -1 control standard were evaluated together with samples in each batch (Table 5).…”
Section: 2 Accuracymentioning
confidence: 99%
“…25 Despite the fact that ICP-MS is highly sensitive, accurate and precise, it is the least used technique in clinical laboratories due to high instrument cost and demanding protocols. [26][27][28] Neutron activation analysis (NAA) is one of the most sensitive techniques for applications in clinical biology. However, analyses are time consuming and therefore largely inappropriate.…”
mentioning
confidence: 99%
“…Microelement content in milk and dairy products is normally very small. The highest levels measured were Zn, Cu, Mg and Cr, which are essential elements and very important for normal metabolism, growth and development (Khan et al, 2014). However, through manufacturing and packaging processes, their contents may be significantly increased.…”
Section: Introductionmentioning
confidence: 99%
“…Elevated concentrations may cause serious health problems. The extent of toxicity is related to factors such as the route of exposure, level of intake, solubility, metal oxidation state, retention percentage, duration of exposure, age, sex, frequency of intake, absorption rate and efficiency of excretion mechanisms (Khan et al, 2014).…”
Section: Introductionmentioning
confidence: 99%