2019
DOI: 10.1109/tpwrs.2018.2871616
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Modal Resonance Between PLL and DC-Link Voltage Control in Weak-Grid Tied VSCs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
27
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 78 publications
(27 citation statements)
references
References 26 publications
0
27
0
Order By: Relevance
“…This is contrary to the benefits of the reduction of the bandwidth for the DVC from the case of the Y dd . This is the result of a resonance between the DVC and the PLL as acknowledged in [38]. As such, a change in closed-loop bandwidth of the DVC moves the resonance; whereas a change in closed-loop bandwidth of the PLL increases or decreases the severity of the resonance.…”
Section: B Decomposition Of Y(s)mentioning
confidence: 99%
“…This is contrary to the benefits of the reduction of the bandwidth for the DVC from the case of the Y dd . This is the result of a resonance between the DVC and the PLL as acknowledged in [38]. As such, a change in closed-loop bandwidth of the DVC moves the resonance; whereas a change in closed-loop bandwidth of the PLL increases or decreases the severity of the resonance.…”
Section: B Decomposition Of Y(s)mentioning
confidence: 99%
“…The drawbacks of the PLL are its slow dynamic response [16] and complexity. FLL has faster dynamic responses [17][18][19].…”
Section: Introductionmentioning
confidence: 99%
“…For this control strategy, a phase-locked loop (PLL) is commonly adopted, which functions to synchronize the wind control system with a power grid by tracking the phase angle of converter terminal bus voltage. However, several literatures have demonstrated that the dynamics of PLL may exhibit an adverse effect on the stability of VSCs that are connected to weak AC grids [5][6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…This effect is also certified in [6] for a photovoltaic inverter. Literature [7], from the perspective of modal resonance, illustrates that the interactions between PLL and DC-link voltage control can lead to damping degradation of the closed-loop system, and weak grid integration will aggravate this side effect. The partial-VSC interfaced doubly-fed induction generator (DFIG) is also found to suffer similar instabilities due to PLL, except for the full-VSC based permanent magnetic synchronous generator (PMSG) [8].…”
Section: Introductionmentioning
confidence: 99%