2005 IEEE 36th Power Electronics Specialists Conference 2005
DOI: 10.1109/pesc.2005.1581773
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of New Step-up and Step-down Direct Symmetric 18-pulse Topologies for Aircraft Autotransformer-Rectifier Units

Abstract: Among possible 18-pulse Autotransformer-Rectifier-Unit (ATRU) topologies, Direct Symmetric circuit (DS-ATRU) demonstrates relatively low complexity, it is insensitive to impedance mismatch and distortions of input voltage and has low common mode voltage. This paper proposes new step-up and stepdown Direct Symmetric 18-pulse ATRU topologies for aircraft application. Serious study of proposed topologies was performed. The authors analyzed the kVA ratings, effects of leakage inductance on compliance with input cu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2008
2008
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 27 publications
(12 citation statements)
references
References 17 publications
0
12
0
Order By: Relevance
“…Finally, from the equations of currents in the time domain given by (26), the RMS value of the currents drawn from the grid are obtained by (27).…”
Section: Dds-18patru: Theoretical Waveform Of Input Line Current With...mentioning
confidence: 99%
“…Finally, from the equations of currents in the time domain given by (26), the RMS value of the currents drawn from the grid are obtained by (27).…”
Section: Dds-18patru: Theoretical Waveform Of Input Line Current With...mentioning
confidence: 99%
“…Scheme A is a well known 18-pulse rectifier [1,6] which has a symmetrical nine-phase input voltages with a phase-shift angle of 40˚. Each diode conducts the dc current during 40˚.…”
Section: Five Practical Schemesmentioning
confidence: 99%
“…The isolated transformer, such as D/Y/D transformer, has the problem of unbalanced leakage inductance of the coil winding which can lead to noncharacteristic harmonics in input line currents. Moreover, the transformer with isolation connection has large capacity which may lead to high system cost (Lucía et al, 2014;Martinius et al, 2002;Uan-Zo-li et al, 2006). To the autotransformer, there are not only magnetic coupling but also circuit coupling between the primary and secondary windings, which makes the capacity of the autotransformer much smaller than that of the isolation transformer.…”
Section: Introductionmentioning
confidence: 99%