2022
DOI: 10.1016/j.jes.2021.08.004
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of per- and polyfluoroalkyl substances in Houston Ship Channel and Galveston Bay following a large-scale industrial fire using ion-mobility-spectrometry-mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 19 publications
(11 citation statements)
references
References 47 publications
0
11
0
Order By: Relevance
“…While these analyses are commonly performed for PFAS, Figure illustrates the various relationships that result for the mass defect and KMD analyses. To evaluate the mass defect and KMDs for the xenobiotics studied, eqs – were utilized. ,, The scalar factor in eq is obtained as the nominal mass of the target compound divided by its exact mass, so it varies for each repeating unit or functional group of interest. For example, for CF 2 , it is 50/49.9968 and for CH 2 , it is 14/14.0156 (showing the exact mass to 4 decimal points).…”
Section: Resultsmentioning
confidence: 99%
“…While these analyses are commonly performed for PFAS, Figure illustrates the various relationships that result for the mass defect and KMD analyses. To evaluate the mass defect and KMDs for the xenobiotics studied, eqs – were utilized. ,, The scalar factor in eq is obtained as the nominal mass of the target compound divided by its exact mass, so it varies for each repeating unit or functional group of interest. For example, for CF 2 , it is 50/49.9968 and for CH 2 , it is 14/14.0156 (showing the exact mass to 4 decimal points).…”
Section: Resultsmentioning
confidence: 99%
“…Even though there were inconsistencies in some sampling areas due to post-hurricane road closures, the attempt to establish a typical profile of air quality in the same large area allowed us to draw conclusions about hurricane Florence-related component in these trends. The post-event "background" is frequently the only option for determining the effects of the disaster as compared to pre-existing contamination [35][36][37][38]. In addition, studies that provide a temporal analysis of environmental exposures [36,37] establish the point of reference for the future investigation and will enable more expedient determination of the potential impacts.…”
Section: Discussionmentioning
confidence: 99%
“…All nontargeted analyses were performed using a 6560 IMS-QTOF MS (Agilent Technologies) as detailed previously [ 30 , 36 ]. All individual standards for pesticide parent compounds (n = 20) and known metabolites (n = 10) were directly injected in triplicate into the electrospray ionization (ESI) source (positive and negative mode) and atmospheric pressure photo-ionization (APPI, negative mode only) to obtain collision cross section (CCS) and mass-to-charge ratio ( m / z ) values.…”
Section: Methodsmentioning
confidence: 99%
“…Nontargeted analyses through high-resolution mass spectrometry enable the rapid characterization of hundreds to thousands of compounds in a given environmental or biological sample [ 29 ]. This approach has been previously shown to provide a more comprehensive compositional characterization of environmental contaminant presence in the environment compared to targeted methods [ 30 ]. Recent advances in analytical tools including ion mobility spectrometry–mass spectrometry (IMS-MS) facilitate nontargeted analyses in a rapid manner and have shown to be an appealing technique for nontargeted metabolomics [ 31 , 32 ].…”
Section: Introductionmentioning
confidence: 99%