The 4th International Electronic Conference on Sensors and Applications 2017
DOI: 10.3390/ecsa-4-04896
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Piezoelectric Diaphragms in Impedance-Based Damage Detection in Large Structures

Abstract: Abstract:The use of low-cost transducers such as piezoelectric diaphragms in structural health monitoring (SHM) applications based on the electromechanical impedance (EMI) method has grown in recent years. Although many studies report the feasibility of such transducers for impedance-based damage detection, the experiments are typically performed on small structures. Therefore, the objective of this work is to perform an experimental analysis of the feasibility of the piezoelectric diaphragms for the detection… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
5
2
1

Relationship

3
5

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 15 publications
0
10
0
Order By: Relevance
“…For greater changes of capacitance CL > 15 pF, the frequency change * is a lot smaller. * ( ) = 1 In order to calculate the influence of the series capacitance C L (Figure 3) on the series resonance frequency f s , the crystal resistance R 1 (Equation (4)) is neglected (R 1 = 0), so that the series impedance is obtained for the series quartz coupling and the series capacitance [6,18,23,24].…”
Section: Load Capacitance Influence On Resonancementioning
confidence: 99%
“…For greater changes of capacitance CL > 15 pF, the frequency change * is a lot smaller. * ( ) = 1 In order to calculate the influence of the series capacitance C L (Figure 3) on the series resonance frequency f s , the crystal resistance R 1 (Equation (4)) is neglected (R 1 = 0), so that the series impedance is obtained for the series quartz coupling and the series capacitance [6,18,23,24].…”
Section: Load Capacitance Influence On Resonancementioning
confidence: 99%
“…The specific transducers used in this study were piezoelectric diaphragms, which have similar characteristics to conventional PZT ceramics [9,10]. The buzzer diaphragms each have a circular brass plate whose dimensions are 20 mm × 0.2 mm that houses a circular piezoelectric ceramic with the dimensions 14 mm × 0.42 mm, which is coated by a metallic film, as shown in Figure 1.…”
Section: Piezoelectric Sensors: Reviewmentioning
confidence: 99%
“…For example, damage in metallic materials generates acoustic waves between 20 and 500 kHz, which is easily detectable by this kind of sensor. The transducers used in this work were the piezoelectric diaphragms, which have similar characteristics to conventional lead zirconate titanate (PZT) ceramics [11,12]. The piezoelectric diaphragms consist of a circular brass plate, with dimensions of 35 × 0.2 mm, and a circular piezoelectric ceramic, with dimensions of 23 × 0.22 mm and an attenuation of 3 dB at 225 kHz [9].…”
Section: Piezoelectric Transducers and Ae Damage Detectionmentioning
confidence: 99%