Analysis of soil and sediment samples by laser ablation inductively coupled plasma mass spectrometry

Abstract: The analysis of soil and sediment samples using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS ) was studied. Solution-based calibration was used for the quantification of trace elements in these samples. In most cases, the measured concentrations were within ±20% of the certified values using 60Ni or 107Ag as the internal standard. Measurements with Ag were carried out to investigate whether an internal standard could be spiked into soils for quantification purposes. The influence of p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
46
0
2

Year Published

2000
2000
2020
2020

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 64 publications
(49 citation statements)
references
References 15 publications
1
46
0
2
Order By: Relevance
“…to <1 μm) [128]. If the particle size of the sample powder is relatively large or if the pellet is not sufficiently compacted, selective ablation of different minerals, signal variations caused by powder outbreak during ablation and the incomplete vaporization of particles could result in poor precision and accuracy [28,135]. The addition of binders could result in the production of discs with greater mechanical stability than that of discs obtained by pressing the sample alone, and the use of such discs could reduce signal instability caused by powder outbreak ablation [127,136].…”
Section: Bulk Analyses Of Whole-rock and Soil Samplesmentioning
confidence: 99%
See 2 more Smart Citations
“…to <1 μm) [128]. If the particle size of the sample powder is relatively large or if the pellet is not sufficiently compacted, selective ablation of different minerals, signal variations caused by powder outbreak during ablation and the incomplete vaporization of particles could result in poor precision and accuracy [28,135]. The addition of binders could result in the production of discs with greater mechanical stability than that of discs obtained by pressing the sample alone, and the use of such discs could reduce signal instability caused by powder outbreak ablation [127,136].…”
Section: Bulk Analyses Of Whole-rock and Soil Samplesmentioning
confidence: 99%
“…If internal standard normalization is used, the element used as an internal standard should be analyzed using other independent methods (e.g. XRF or wet chemical methods) or added into the powder sample during the preparation of the pressed pellet or whole-rock glass [28,136]. The bulk content of volatile components (such as H 2 O and CO 2 ) in the sample should be accurately measured using other independent methods if the summed metal oxide normalization technique is used.…”
Section: Bulk Analyses Of Whole-rock and Soil Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…Several authors [135][136][137] have described the application of LA-ICP-MS for the analysis of whole-rock geological samples, such as pressed power pellets and lithium metaborate fusions.…”
Section: Bulk Analysismentioning
confidence: 99%
“…For glasses, small size particles are condensed from vapor, whereas the recoil plasma interacting with the melted layer and an exfoliation process mainly produce larger particles and bulk solid flakes (31). For pressed pellets, particle generation processes also include shockwave spallation (52). F or high-density alloys, thermal vaporization may dominate the formation of small particles.…”
Section: Particle Generation From Laser Ablation Processesmentioning
confidence: 99%