2021
DOI: 10.3390/en14020474
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Subsynchronous Torsional of Wind–Thermal Bundled System Transmitted via HVDC Based on Signal Injection Method

Abstract: With the development of large-scale new energy, the wind–thermal bundled system transmitted via high-voltage direct current (HVDC) has become the main method to solve the problem of wind power consumption. At the same time, the problem of subsynchronous oscillation among wind power generators, high-voltage direct current (HVDC), and synchronous generators (SGs) has become increasingly prominent. According to the dynamic interaction among doubly fed induction generators (DFIGs), HVDC, and SGs, a linearization m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…Combining Equations ( 6), ( 8) and ( 11) divides out rotor voltage and current. The DFIG input impedance Z rdfig after considering the rotor controller is as follows: (12) where…”
Section: Dfig-based Frequency-domain Impedance Model Considering Rsc ...mentioning
confidence: 99%
See 1 more Smart Citation
“…Combining Equations ( 6), ( 8) and ( 11) divides out rotor voltage and current. The DFIG input impedance Z rdfig after considering the rotor controller is as follows: (12) where…”
Section: Dfig-based Frequency-domain Impedance Model Considering Rsc ...mentioning
confidence: 99%
“…The equivalent resistance R rdfig of the DFIG after considering the rotor converter can be obtained from Equation (12), as shown in Equation ( 13):…”
Section: Dfig-based Frequency-domain Impedance Model Considering Rsc ...mentioning
confidence: 99%
“…However, as the scale of wind power grid connection increases, subsynchronous oscillation accidents in wind power grid connection occur frequently [4][5][6]. In 2015, an SSO accident occurred at a direct drive wind farm in Hami, Xinjiang, when it was connected to the Xinjiang power grid via a long-distance non series compensation line, posing a serious threat to the safe operation of the power system [7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…Under the operating condition that direct-drive wind farms located in close proximity to the HVDC rectifier station, the mechanism of sub-synchronous interaction between them is explained in detail in Reference [13], and an analysis was conducted to explore the impact of controller parameters on SSO mode damping. In Reference [14], the additional excitation signal injection method is used to analyze the effect of control parameters, operating wind speed, and the number of grid-connected units on the damping characteristics of each torsional vibration mode of the synchronous generator set when the DC transmission capacity is fixed. Additionally, the mechanism of negative damping torsional vibration of the synchronous generator set shaft system is revealed.…”
Section: Introductionmentioning
confidence: 99%