Analysis of the Causes of the Emergency Shutdown of Natural Gas-Fired Water Peak Boilers at the Large Municipal Combined Heat and Power Plant
Marcin Trojan,
Piotr Dzierwa,
Jan Taler
et al.
Abstract:The paper presents a cause-and-effect analysis of the failure of a 130 MWt gas-fired water boiler. The fault was a rupture of the helically finned tubes in the first rows of the second-stage water heater (ECO2). The high frequency of failures forced the boiler user to investigate their causes. The rapid drop in water flow in the ECO2 and the tightly finned pipes suggested that the permissible operating temperature of the steel used was exceeded. The only possible way to assess the working conditions was throug… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.