2023
DOI: 10.3390/en16176278
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the Causes of the Emergency Shutdown of Natural Gas-Fired Water Peak Boilers at the Large Municipal Combined Heat and Power Plant

Marcin Trojan,
Piotr Dzierwa,
Jan Taler
et al.

Abstract: The paper presents a cause-and-effect analysis of the failure of a 130 MWt gas-fired water boiler. The fault was a rupture of the helically finned tubes in the first rows of the second-stage water heater (ECO2). The high frequency of failures forced the boiler user to investigate their causes. The rapid drop in water flow in the ECO2 and the tightly finned pipes suggested that the permissible operating temperature of the steel used was exceeded. The only possible way to assess the working conditions was throug… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
0
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
references
References 34 publications
0
0
0
Order By: Relevance