Analysis of the Diversity of Substrate Utilisation of Soil Bacteria Exposed to Cd and Earthworm Activity Using Generalised Additive Models

Abstract: Biolog EcoPlates™ can be used to measure the carbon substrate utilisation patterns of microbial communities. This method results in a community-level physiological profile (CLPP), which yields a very large amount of data that may be difficult to interpret. In this work, we explore a combination of statistical techniques (particularly the use of generalised additive models [GAMs]) to improve the exploitation of CLPP data. The strength of GAMs lies in their ability to address highly non-linear relationships betw… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
29
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 54 publications
(32 citation statements)
references
References 55 publications
2
29
0
1
Order By: Relevance
“…The absorbance was measured with DIALAB EL800 Microplate Reader at every 24 hours for 120 hours at 490 nm wavelength. The Biolog EcoPlate method usually measures optical density (OD) at 590 nm because the peak absorbance of the tetrazolium dye occurs at 590 nm (Garland, 1997, Muñiz et al, 2014, Garau et al, 2007. Nevertheless we used absorbance values at 490 nm because our microplate reader was equipped with 405, 450, 490 and 630 nm filters, but the optimal OD values were provided at 490 nm (Nagy et al, 2013).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The absorbance was measured with DIALAB EL800 Microplate Reader at every 24 hours for 120 hours at 490 nm wavelength. The Biolog EcoPlate method usually measures optical density (OD) at 590 nm because the peak absorbance of the tetrazolium dye occurs at 590 nm (Garland, 1997, Muñiz et al, 2014, Garau et al, 2007. Nevertheless we used absorbance values at 490 nm because our microplate reader was equipped with 405, 450, 490 and 630 nm filters, but the optimal OD values were provided at 490 nm (Nagy et al, 2013).…”
Section: Methodsmentioning
confidence: 99%
“…The Shannon index (H) resulted from H= -ΣPi ln(Pi), where Pi=ODi/ ΣODi, which is the proportional color development of the well over total color development of all wells of a plate (Garland and Mills, 1991, Tam et al, 2001, Muñiz et al, 2014. The number of substrates oxidized (substrate richness, SR) was calculated as the sum of the number of cells where ODi value reached 0.15 after 120 h (Garau et al, 2007).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…EcoPlate (Biolog) is a rapid and convenient method to mainly investigate and estimate the impact of stressors on microbial communities from several environmental sources: soil (Muniz et al, 2014;FloresRentería et al, 2016), water (Patel et al, 2014;Xiao;Tinglin;Haihan, 2015), wastewater from different technologies (Jałowiecki et al, 2016) and many other sources.…”
Section: Introductionmentioning
confidence: 99%