2013
DOI: 10.1016/j.nima.2012.08.014
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the imaging performance in indirect digital mammography detectors by linear systems and signal detection models

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(9 citation statements)
references
References 48 publications
0
9
0
Order By: Relevance
“…In Table 1 , the results of the ANOVA test are demonstrated. As an initial choice, the large area lesions of 40 × 40 pixels were selected, since the lesions with larger areas are easier to distinguish [ 9 , 31 , 36 ]. It can be seen in Table 1 that, for the Mo/Mo 28 kVp irradiation conditions for the 4.2 cm breast thickness and the 0.1 cm lesion thickness, the adipose tissue is statistically comparable with the breast tissue background ( p > 0.05), while for the blood and the muscle tissue, the signal is significantly different.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…In Table 1 , the results of the ANOVA test are demonstrated. As an initial choice, the large area lesions of 40 × 40 pixels were selected, since the lesions with larger areas are easier to distinguish [ 9 , 31 , 36 ]. It can be seen in Table 1 that, for the Mo/Mo 28 kVp irradiation conditions for the 4.2 cm breast thickness and the 0.1 cm lesion thickness, the adipose tissue is statistically comparable with the breast tissue background ( p > 0.05), while for the blood and the muscle tissue, the signal is significantly different.…”
Section: Resultsmentioning
confidence: 99%
“…The previously described software phantom was assumed to be irradiated by four mammographic X-ray spectra with anode/filter KVp combination as follows [ 31 ]: (a) Mo/Mo 28 kVp, (b) Mo/Mo 32 kVp, (c) W/Rh 28 kVp and (d) W/Rh 32 kVp. The Mo filtration was 0.03 mm and the Rh filtration was 0.06 mm [ 31 ]. The entrance surface air KERMA of the spectra was 5 mGy except in the case of Mo/Mo 32 kVp, which was 3 mGy.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Monte Carlo) or the use of Linear Cascaded Systems Theory (LCST) where the stages of image formation from X-ray absorption to pixel creation can be represented by statistical processes. LCST theory has been utilized in the past to determine general mathematical formulas which describe noise and signal transfer in the detector [3]- [9]. In addition, LCST processes have been successfully employed to investigate the image quality metrics of CR systems [10].…”
Section: Introductionmentioning
confidence: 99%