2020
DOI: 10.1088/1757-899x/966/1/012056
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the influence of the parameters of the power supply network on the operating modes of the electric drives of the stands of the hot rolling mill 1700 of ArcelorMittal Temirtau JSC

Abstract: The finishing group of stands of the 1700 SRS-1 continuous mill of ArcelorMittal Temirtau JSC is characterized by high rolling speeds and high productivity. The use of DC motors as power sources for the main drives of the stands of high-power thyristor converter units significantly affects the nature of the operating modes of the power supply system and the quality of electricity on the buses of the SRS-1 substation. Experiments were performed to study the electricity grid supply substation in which the basic … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 4 publications
0
1
0
Order By: Relevance
“…To assess the power supply system state of ArcelorMittal Temirtau JSC SRS-1 1,700 hot-rolling mill some experiments were carried out to study the substation 6 power supply network which provides energy consumption for the mill main drives. The electricity quality main indicators were determined and while being rolled voltage dips register diagram was made in accordance with the experimental studies results of power supply system data of ArcelorMittal Temirtau JSC SRS-1 1,700 hotrolling mill that were obtained due to application of "Resurs-UF2M" [39] energy quality indicators device certified on the territory of the Republic of Kazakhstan [40]. Figure 3 The register analysis indicates that the voltage dips can be observed during the entire rolling process and their average values exceed the maximum allowable values regulated by the 32,144-2,013 adopted state standards (Figure 3) [41].…”
Section: Methodsmentioning
confidence: 99%
“…To assess the power supply system state of ArcelorMittal Temirtau JSC SRS-1 1,700 hot-rolling mill some experiments were carried out to study the substation 6 power supply network which provides energy consumption for the mill main drives. The electricity quality main indicators were determined and while being rolled voltage dips register diagram was made in accordance with the experimental studies results of power supply system data of ArcelorMittal Temirtau JSC SRS-1 1,700 hotrolling mill that were obtained due to application of "Resurs-UF2M" [39] energy quality indicators device certified on the territory of the Republic of Kazakhstan [40]. Figure 3 The register analysis indicates that the voltage dips can be observed during the entire rolling process and their average values exceed the maximum allowable values regulated by the 32,144-2,013 adopted state standards (Figure 3) [41].…”
Section: Methodsmentioning
confidence: 99%