2020
DOI: 10.1109/tla.2020.9082214
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the Power Quality of a Grid-Connected Photovoltaic System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 5 publications
0
4
0
2
Order By: Relevance
“…The purpose of the multifunctional system is for obtaining a sinusoidal current of the utility i s , using the relationship 5. Assume that i l can be expressed as (6):…”
Section: Multifunctional Inverter 221 Predictive Direct Power Controlmentioning
confidence: 99%
See 1 more Smart Citation
“…The purpose of the multifunctional system is for obtaining a sinusoidal current of the utility i s , using the relationship 5. Assume that i l can be expressed as (6):…”
Section: Multifunctional Inverter 221 Predictive Direct Power Controlmentioning
confidence: 99%
“…Particularly, photovoltaic (PV) power generation, is conducting to a fast growing integration of renewable energy sources as a distributed generation (DG) system into the utility grid. However, a large scale penetration of these sources poses serious problems, as it can threat the power system's stability and reliability [4]- [6]. Meanwhile, the main challenge of theses systems is the extraction of the maximum power of the PV system through maximum power point tracking (MPPT)s algorithms, as well as, the power quality injected to the grid, which is in direct relation with power converter and its control strategy [7], [8].…”
Section: Introductionmentioning
confidence: 99%
“…También en [28], se analizó el impacto de otro sistema FV conectado a la red, evaluando los indicadores de CEE en función de los niveles especificados en las normas que regulan al Sistema Eléctrico Nacional local. Los resultados obtenidos mediante el uso de un dispositivo analizador de redes eléctricas en la salida del inversor del sistema conectado a la red, mostraron que el comportamiento de la distorsión armónica de corriente aumentaba en los períodos del día con poca potencia activa, determinándose que el rendimiento del inversor en relación con los criterios de CEE era satisfactorio a plena carga.…”
Section: Revista De Ciencias Tecnológicas (Recit) Volumen 6 (1): 1-13unclassified
“…No caso de sistemas conectados, também são responsáveis pela sincronia com a rede elétrica. Na mesma direção que este artigo, outros trabalhos [16,17,18,19] mostram os resultados de sistemas fotovoltaicos em funcionamento, respectivamente na cidade de Quito/Equador, no estado do Piauí/Brasil, no Rio Grande do Norte-Brasil e na Argentina. A diferença que se percebe entre esses trabalhos e o presente artigo, como já dito, é a capacidade de monitoramento de diversas grandezas elétricas nas usinas fotovoltaicas e demais prédios dos campi da UFG, compreendendo 120 medidores espalhados pelos diversos barramentos dentro das instalações da instituição.…”
Section: Sistemas Fotovoltaicosunclassified