2019
DOI: 10.1007/s10450-019-00071-z
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the systematic force-transmission error of the magnetic-suspension coupling in single-sinker densimeters and commercial gravimetric sorption analyzers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
79
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

5
1

Authors

Journals

citations
Cited by 32 publications
(81 citation statements)
references
References 29 publications
2
79
0
Order By: Relevance
“…A schematic diagram of the densimeter, presented by Richter et al [11], is given in the Online Resource 1. In one of our latest papers [6], we presented a few improvements of the core apparatus to reduce diffusion effects and the force-transmission error (FTE) [22,23]. Here, we summarize the description of the apparatus presented by Richter et al [11].…”
Section: Apparatus Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…A schematic diagram of the densimeter, presented by Richter et al [11], is given in the Online Resource 1. In one of our latest papers [6], we presented a few improvements of the core apparatus to reduce diffusion effects and the force-transmission error (FTE) [22,23]. Here, we summarize the description of the apparatus presented by Richter et al [11].…”
Section: Apparatus Descriptionmentioning
confidence: 99%
“…where fluid denotes the fluid density. When weighing the sinker inside the evacuated measuring cell via the magnetic-suspension coupling, the weighing result is not the mass of the sinker, m S , but a slightly different result, m * S,vac , which is the result of a small FTE of the magnetic-suspension coupling [22,23]. Rearranging Eq.…”
Section: Apparatus Descriptionmentioning
confidence: 99%
“…The design of the cryogenic densimeter, the temperature and pressure measurement and the implementation of a special "VLE-cell" as a novel feature were described in detail previously [9][10][11]. In our latest paper [5], we presented some improvements of the core apparatus to reduce diffusion effects and the force-transmission error (FTE) [22,23]. Here, for the convenience of the readers of the present data paper, we summarize the description of the apparatus presented by Richter et al [11].…”
Section: Apparatus Descriptionmentioning
confidence: 99%
“…where fluid is the density of the fluid. When weighing the sinker inside the evacuated measuring cell via the magnetic-suspension coupling, the weighing result is not the mass of the sinker, m S , but a slightly different result, m * S,vac , due to a small FTE of the magnetic-suspension coupling [22,23]. Rearranging Eq.…”
Section: Apparatus Descriptionmentioning
confidence: 99%
See 1 more Smart Citation