2008
DOI: 10.1002/jssc.200800171
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of the volatile chemical markers of explosives using novel solid phase microextraction coupled to ion mobility spectrometry

Abstract: Ion mobility spectrometry (IMS) is routinely used in screening checkpoints for the detection of explosives and illicit drugs but it mainly relies on the capture of particles on a swab surface for the detection. Solid phase microextraction (SPME) has been coupled to IMS for the preconcentration of explosives and their volatile chemical markers and, although it has improved the LODs over a standalone IMS, it is limited to sampling in small vessels by the fiber geometry. Novel planar geometry SPME devices coated … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
44
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 76 publications
(44 citation statements)
references
References 14 publications
0
44
0
Order By: Relevance
“…the interface is not considered robust). Further experimentation has been performed by Guerra et al using a novel planar SPME device which negates the need for varying fiber interfaces [98]. This geometry (~ 65-70µm thick) increases the surface area and volume which enhances analyte recovery.…”
Section: Field Portable Instrumentationmentioning
confidence: 99%
“…the interface is not considered robust). Further experimentation has been performed by Guerra et al using a novel planar SPME device which negates the need for varying fiber interfaces [98]. This geometry (~ 65-70µm thick) increases the surface area and volume which enhances analyte recovery.…”
Section: Field Portable Instrumentationmentioning
confidence: 99%
“…5. PDMS coated glass slides: The polydimethylsiloxane (PDMS) coated glass slides were developed by Guerra et al, at FIU as an alternate SPME geometry 25 . They have been shown to have effective extractions of organic volatiles from the headspace of target matrices.…”
Section: Resultsmentioning
confidence: 99%
“…In a similar study, SPME extraction capability was compared to planar solid phase microextraction for the analysis of explosives in IMS. The results yield greater amount of TNT being extracted by PSPME [Guerra et al, 2008].…”
Section: Research Motivationmentioning
confidence: 85%
“…Portable instruments and tools have been developed with several applications in illicit drugs and explosives detection, environmental monitoring, and food authentication [Perr et al, 2005;Guerra et al, 2008;Wong et al, 2013;Huang et al, 2015;Soria et al, 2015]. Some of the instruments that have been adapted for field analysis include: Gas chromatography mass spectrometry (GC-MS), ion mobility spectrometry (IMS), x-ray fluorescence spectroscopy (XRF), and laser induced breakdown spectroscopy (LIBS) [Fortes et al, 2010].…”
Section: Research Motivationmentioning
confidence: 99%