2016
DOI: 10.1016/j.foodchem.2015.08.050
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of trace levels of sulfonamides in fish tissue using micro-scale pipette tip-matrix solid-phase dispersion and fast liquid chromatography tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
32
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 59 publications
(32 citation statements)
references
References 28 publications
0
32
0
Order By: Relevance
“…The 96‐well p‐SPE method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), and intra‐ and inter‐day precision and accuracy, recovery, and stability. The detailed procedure was referred to our previous publication . In brief, a total of six concentration levels ranging from LOQ to 1000 ng/mLwas analyzed for calculating the matrix‐matched standard curves.…”
Section: Methodsmentioning
confidence: 99%
“…The 96‐well p‐SPE method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), and intra‐ and inter‐day precision and accuracy, recovery, and stability. The detailed procedure was referred to our previous publication . In brief, a total of six concentration levels ranging from LOQ to 1000 ng/mLwas analyzed for calculating the matrix‐matched standard curves.…”
Section: Methodsmentioning
confidence: 99%
“…Sulfonamides are a series of amphoteric molecules that have a strong polarity and thermal instability [137,138]; thus, HPLC is typically utilized for the separation of different kinds of sulfonamides with its excellent separation capacity. Detectors coupled with HPLC include UV [71,72], FL [73], DAD [33,74,75], and MS [52,55,139,140]. Among these, the UV detector was most widely used for its inexpensiveness and utility, and the wavelengths of sulfonamides are from 270 to 280 nm or at 255 nm [106].…”
Section: Instrumental Analysismentioning
confidence: 99%
“…As a confirmatory detector, MS can provide information about the molecular structures and quantitative data on the analytes with high sensitivity and selectivity. Furthermore, for the purpose of enhancing sensitivity and accuracy, MS/MS [50,51,53,55] has been utilized for the analyses of sulfonamides. With the advantages and disadvantages mentioned above, MS/MS is outstanding compared with the other detectors.…”
Section: Instrumental Analysismentioning
confidence: 99%
“…Recently, there are several analytical methods based on spectrophotometric or electrochemical detection , most of which for the determination of MG and LMG in a number of aquatic species tissues are based on MS detection, because this detection method provides greater sensitivity, specificity and with better values of the figures of merit. LC‐MS/MS is the most preferred method for determination and confirmation of drug residues . A fast LC–TOF/MS method was employed by Villar‐Pulido et al.…”
Section: Introductionmentioning
confidence: 99%