Analysis of uncertainties in Gafchromic® EBT film dosimetry of photon beams

Abstract: Radiotherapy today employs complex techniques in order to achieve the best possible conformity of the delivered dose to the target volume. When using dynamic dose delivery techniques, it is especially important to verify the delivered dose at as many representative points as possible. As a continuous medium, Gafchromic EBT film offers an excellent spatial resolution which, together with improvements in sensitivity as compared to older types of radiochromic films, make it a promising candidate for this purpose.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
168
1

Year Published

2010
2010
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 128 publications
(174 citation statements)
references
References 7 publications
5
168
1
Order By: Relevance
“…In 2009, the GAFCHROMIC EBT film was replaced by the GAFCHROMIC EBT2 film that incorporates a yellow marker dye in the active layer and a synthetic polymer as the binder component. Several works have been published studying some EBT and EBT2 properties, such as film homogeneity, ( 1 , 2 ) scanning orientation dependence, ( 3 7 ) energy dependence, ( 4 , 8 10 ) absorption spectra, ( 11 ) postcoloration behavior, ( 2 , 4 5 , 7 8 , 12 13 ) high‐dose dependence, ( 7 ) temperature dependence, ( 7 , 14 15 ) and ambient light sensitivity. ( 7 ) …”
Section: Introductionmentioning
confidence: 99%
“…In 2009, the GAFCHROMIC EBT film was replaced by the GAFCHROMIC EBT2 film that incorporates a yellow marker dye in the active layer and a synthetic polymer as the binder component. Several works have been published studying some EBT and EBT2 properties, such as film homogeneity, ( 1 , 2 ) scanning orientation dependence, ( 3 7 ) energy dependence, ( 4 , 8 10 ) absorption spectra, ( 11 ) postcoloration behavior, ( 2 , 4 5 , 7 8 , 12 13 ) high‐dose dependence, ( 7 ) temperature dependence, ( 7 , 14 15 ) and ambient light sensitivity. ( 7 ) …”
Section: Introductionmentioning
confidence: 99%
“…Figure 1 shows the layout of the radiator side section. Radiochromic films have been widely used in dosimetric procedures, where it is necessary to know the planar behavior of doses [3] [4]. Accordingly, to determine the distribution of doses on the surface of the sample holder, radiochromic films of the EBT-3 generation from ISP were used.…”
Section: Methodsmentioning
confidence: 99%
“…Ahead of scanning, the scanner window was wiped clean with alcohol and the outer frame of the scanner plate was marked for identification of the center point of the plate to enhance film positioning reproducibility. Since the response of the scanner is stabilized after the third scan [18][19], data from the first three scans were discarded in image acquisition in order to avoid the warm-up effect of the scanner lamp. Background subtraction was conducted by scanning of an unexposed film from the same batchnumber packet.…”
Section: Scanner (Epson Expression 1680 Pro Epsonmentioning
confidence: 99%