2015
DOI: 10.1016/j.ijms.2015.03.004
|View full text |Cite
|
Sign up to set email alerts
|

Analytical procedure of neon measurements on GV 5400 noble gas mass spectrometer and its evaluation by quartz standard CREU-1

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
10
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 20 publications
0
10
1
Order By: Relevance
“…The calculated cosmogenic 21 Ne abundances from 22 aliquots of CREU-1 (Table 1) all agree within 2σ with their arithmetic mean (348 ±10 x 10 6 atoms/g; ±2σ); thus, we may calculate an error-weighted mean: 348 ± 2 x 10 atoms/g (±2σ), which is indistinguishable from the published value (348± 10 x 10 6 atoms/g; Vermeesch et al, 2015). We conclude that the reproducibility and accuracy of the current set up at the University of Cologne for determining cosmogenic 21 Ne in quartz is similar to or better than those reported for other laboratories worldwide (Vermeesch et al, 2015;Farley et al, 2020;Ma et al, 2015). Vermeesch et al, 2015).…”
Section: Performancecontrasting
confidence: 46%
See 1 more Smart Citation
“…The calculated cosmogenic 21 Ne abundances from 22 aliquots of CREU-1 (Table 1) all agree within 2σ with their arithmetic mean (348 ±10 x 10 6 atoms/g; ±2σ); thus, we may calculate an error-weighted mean: 348 ± 2 x 10 atoms/g (±2σ), which is indistinguishable from the published value (348± 10 x 10 6 atoms/g; Vermeesch et al, 2015). We conclude that the reproducibility and accuracy of the current set up at the University of Cologne for determining cosmogenic 21 Ne in quartz is similar to or better than those reported for other laboratories worldwide (Vermeesch et al, 2015;Farley et al, 2020;Ma et al, 2015). Vermeesch et al, 2015).…”
Section: Performancecontrasting
confidence: 46%
“…Fig. 5: Compilation of measured CGN CREU-1 21 Ne concentrations (±2σ uncertainties), compared to reported 21 Ne concentrations from interlaboratory comparison from Vermeesch et al (2015) and recent data from the Peking noble gas lab from Ma et al (2015). Black bars were considered outliers https://doi.org/10.5194/gchron-2021-11 Preprint.…”
Section: Performancementioning
confidence: 99%
“…Instrumental sensitivity and mass fractionation in the instrument is calculated from repeated analysis of aliquots of Ne in air. In many laboratories the CREU quartz standard(Ma et al 2015;Vermeesch et al 2015) is used as an internal check.The abundance of cosmogenic 21 Ne ( 21 Nec) in samples is calculated assuming that all the measured…”
mentioning
confidence: 99%
“…The 21 Ne/ 20 Ne and 22 Ne/ 20 Ne ratios varied from 0.00836 ± 0.00007 to 0.01379 ± 0.00022 and from 0.1092 ± 0.00036 to 0.1145 ± 0.00063, respectively. The samples contained higher proportions of air than most samples reported in the international calibration exercise [5,24,25]. This may reflect the low temperature and short duration of the pre-extraction bake out.…”
Section: Creu-1 Quartzmentioning
confidence: 83%
“…Air value (black square) from [6,22]. Other data are from [5,24,25]. ETH (Switzerland), BGC (USA), SUERC (UK), GFZ (Germany), CRPG (France), CEA: China Earthquake Administration (PR China), UoC: University of Cologne (Germany).…”
Section: Creu-1 Quartzmentioning
confidence: 99%