2019
DOI: 10.1016/j.jvscit.2019.02.007
|View full text |Cite
|
Sign up to set email alerts
|

Anatomic and hemodynamic investigation of an occluded common carotid chimney stent graft for hybrid thoracic aortic aneurysm repair

Abstract: We examined the possible reasons for common carotid artery chimney stent graft occlusion through computational fluid dynamics analyses of follow-up imaging of a patient-specific aortic configuration reconstructed from computed tomography aortography. Anatomic and hemodynamic parameters were extracted for the bilateral common carotid and subclavian arteries before and after endograft placement. Results suggested that postoperative reduction in lumen diameter within the chimney stent graft combined with an incre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(1 citation statement)
references
References 15 publications
0
1
0
Order By: Relevance
“…In the parallel setting of these devices, adherence of the target vessel to the surrounding structures together with the respiratory movements could move the stented vessel downward, forcing the stent into an angulated segment and leading to kinking. Also, as proven recently by Tricarico et al, 12 lumen diameter reduction due to vessel stenting increases the flow rate within the vessel, producing hemodynamic changes and high wall shear stress that can lead to occlusion of the stentgraft. Also, the stiffness of the guidewire, the length of the CG, and involvement of its distal edge in the angulated segment influence the risk of CG kinking and subsequent occlusion.…”
Section: Discussionmentioning
confidence: 87%
“…In the parallel setting of these devices, adherence of the target vessel to the surrounding structures together with the respiratory movements could move the stented vessel downward, forcing the stent into an angulated segment and leading to kinking. Also, as proven recently by Tricarico et al, 12 lumen diameter reduction due to vessel stenting increases the flow rate within the vessel, producing hemodynamic changes and high wall shear stress that can lead to occlusion of the stentgraft. Also, the stiffness of the guidewire, the length of the CG, and involvement of its distal edge in the angulated segment influence the risk of CG kinking and subsequent occlusion.…”
Section: Discussionmentioning
confidence: 87%