BackgroundThe role of angiotensin-converting enzyme inhibitors (ACEIs) and angiotensin receptor blockers (ARBs) reducing risk of cardiovascular events (CVEs) and preserving kidney function in patients with chronic kidney disease is well-documented. However, the efficacy and safety of these agents in dialysis patients is still a controversial issue.MethodsWe systematically searched MEDLINE, Embase, Cochrane Library and Wanfang for randomized trials. The relative risk (RR) reductions were calculated with a random-effects model. Major cardiovascular events, changes in GFR and drug-related adverse events were analyzed.ResultsEleven trials included 1856 participants who were receiving dialysis therapy. Compared with placebo or other active agents groups, ARB therapy reduced the risk of heart failure events by 33% (RR 0.67, 95% CI 0.47 to 0.93) with similar decrement in blood pressure in dialysis patients. Indirect comparison suggested that fewer cardiovascular events happened during treatment with ARB (0.77, 0.63 to 0.94). The results indicated no significant differences between the two treatment regimens with regard to frequency of myocardial infarction (1.0, 0.45 to 2.22), stroke (1.16, 0.69 to 1.96), cardiovascular death (0.89, 0.64 to 1.26) and all-cause mortality (0.94, 0.75 to 1.17). Five studies reported the renoprotective effect and revealed that ACEI/ARB therapy significantly slowed the rate of decline in both residual renal function (MD 0.93 mL/min/1.73 m2, 0.38 to 1.47 mL/min/1.73 m2) and urine volume (MD 167 ml, 95% CI 21 ml to 357 ml). No difference in drug-related adverse events was observed in both treatment groups.ConclusionsThis study demonstrates that ACE-Is/ARBs therapy decreases the loss of residual renal function, mainly for patients with peritoneal dialysis. Overall, ACE-Is and ARBs do not reduce cardiovascular events in dialysis patients, however, treatment with ARB seems to reduce cardiovascular events including heart failure. ACE-Is and ARBs do not induce an extra risk of side effects.Electronic supplementary materialThe online version of this article (doi:10.1186/s12882-017-0605-7) contains supplementary material, which is available to authorized users.